Progress Lighting AirPro P250072 Installation Manual Download Page 4

1. 

To reduce the risk of electric shock, insure electricity has been 

turned off at the circuit breaker or fuse box before beginning.

2. 

All wiring must be in accordance with the National Electrical 

Code ANSI/NFPA 70-1999 and local electrical codes. 

Electrical installation should be performed by a qualified 

licensed electrician.

3. 

CAUTION: To reduce the risk of personal injury, use only the 

screws provided with the electrical box. 

4. 

The outlet box and support structure must be securely 

mounted and capable of reliably supporting 35 lbs. (15.9 kg). 

Use only cUL Listed outlet boxes marked “Acceptable for Fan 

Support of 35 lbs. (15.9 kg) or less.”

5. 

CAUTION: The fan must be mounted with a minimum of 7 

feet clearance from the trailing edge of the blades to the floor.

6. 

Do not wait for the fan to stop before pressing the reverse 

button. The fan will not reverse direction if the fan is not 

moving.

7. 

Avoid placing objects in path of the blades.

8. 

To avoid personal injury or damage to the fan and other items, 

be cautious when working around or cleaning the fan.

9. 

Do not use water or detergents when cleaning the fan or fan 

blades. A dry dust cloth or lightly dampened cloth will be 

suitable for most cleaning. 

10. 

After making electrical connections, spliced conductors should 

be turned upward and pushed carefully up into electrical box. 

The wires should be spread apart with the grounded conductor 

and the equipment-grounding conductor on one side of the 

electrical box and ungrounded conductor on the other side of 

the electrical box.

11. 

Electrical diagrams are for reference only. Light kits that 

are not packed with the fan must be UL Listed and marked 

suitable for use with the model fan you are installing. Switches 

must be UL General Use Switches. Refer to the instructions 

packaged with the light kits and switches for proper assembly.

12. 

All set screws must be checked and retightened where 

necessary before installation.

13. 

WARNING: To reduce the risk of fire or electric shock, 

this fan should only be used with fan speed control part 

no.  DP-51R, manufactured by DAWNSUN ELECTRONIC 

TECHNOLOGY CO LTD ZHONGSHAN.

14. 

Suitable for use in damp locations. Use only with light kits 

marked “Suitable for use in damp locations.”

 1. Safety Rules

READ AND SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT TO OUTLET BOX MARKED “ACCEPTABLE FOR FAN 

SUPPORT OF 35LBS. (15.9 KG) OR LESS”, AND USE SCREWS PRO-

VIDED WITH THE OUTLET BOX.

TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE 

BLADE BRACKETS (ALSO REFERRED TO AS (“FLANGES”) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN 

THE PATH OF THE BLADES.

TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED 

WITH AN ISOLATION WALL CONTROL/SWITCH.

Summary of Contents for AirPro P250072

Page 1: ...P250072 93153462_A...

Page 2: ...placement After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discretion and shall be pu...

Page 3: ...Safety Rules Unpacking Your Fan Installing Your Fan Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications Table of Contents 1 2 3 6 11 12 12 13...

Page 4: ...ld be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the electrical box and...

Page 5: ...itter and Receiver 11 Extension Lead Wire 1 Mounting Bracket inside canopy 2 6 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy Ring attached 4 Decorative Motor Colla...

Page 6: ...s to mount the electrical box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 20 If the canopy touches do...

Page 7: ...h the ball down rod assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not remove the set screws on the collar on the top of the motor housi...

Page 8: ...toward the electrical box Figure 8 3 Tighten the two screws on the electrical box securely 4 Carefully lift the fan assembly up to the ceiling mounting bracket Make sure the tab on the mounting brack...

Page 9: ...gure 10 Wiring the Fan to the Receiver 1 If using the 6 in ball downrod assembly provided wire the receiver to the fan wires by connecting the molded adaptor plug from this receiver with the molded ad...

Page 10: ...ts with the screws in the canopy Rotate the ring clockwise to lock in place 4 You may now proceed to attaching the fan blades WHEN USING THE STANDARD BALL DOWNROD MOUNTING THE TAB IN THE RING AT THE B...

Page 11: ...from a point on the center of each blade to the point on the ceiling Measure this distance as shown in Figure 14 Rotate the fan until the next blade is positioned for measurement Repeat for each blade...

Page 12: ...ght kit fitter assembly to the wires from the fan motor assembly by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the switch cap Figure 16 4 Push the light kit...

Page 13: ...r 7 If pairing is successful the fan s light kit will flash and the blades will begin to spin 8 Replace the battery cover on the remote control NOTE The remote control has already been paired to the c...

Page 14: ...e the Breeze function this will change your fan speed randomly simulating a relaxing breeze Fan speed LEDs on the fan speed button will illuminate to the corresponding speed Press and release 1 turns...

Page 15: ...AKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the switch ho...

Page 16: ...arantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipmen...

Reviews: