Progres Radiocontrol 6i-6o Manual Download Page 7

User Manual | Radiocontrol 6i-6o  

· 

 

7

Master

5-30 Vdc

5-30 Vdc

Power supply

Outputs

Outputs

Inputs

Inputs

Slave

Outputs

: The outputs are located at the top and are numbered 

R1 to R6

. Each output is 

assigned two terminal points that correspond to the normally open contact of its associated 
relay. The maximum load that can be supported by each of the relays is 5 A at 220 Vac. 

When an output has been activated, the module's 

red LED

 is activated.

To facilitate the passage of the hose from the inputs and outputs of each module to the devices 

to be activated, three cable glands have been placed in the boxes.

Antenna

: The standard system is served with omnidirectional antennas and their respective 

cables, 10 metres long, to connect to the modules. The module output consists of an SMA-type 

female connector, where the 10-metre cable is connected, which is finished with an N connector 

at the other end, where the antenna is connected.

Power supply

: Each of the modules is delivered with a 220 Vac        12 Vdc, 2A transformer, in 

the case of modules powered at 220 Vac.

Power supply

Summary of Contents for Radiocontrol 6i-6o

Page 1: ...eans that each individual unit is a transmitter and receiver at the same time so that eventually the remote equipment to which orders are sent can also send the status of its inputs The signals are tr...

Page 2: ...red from the factory to operate in two different modes Standard mode has a minimum of two modules and a maximum of seven modules Now in all cases there will only be one master and the rest of the modu...

Page 3: ...le master slave pairs although in this case the four masters use a single antenna and are interconnected via cable RS485 In this way the operation is much more optimal at the radio electric level sinc...

Page 4: ...Slave In standby 28 40 Communicating 1 sec 70 100 Output power 500 mW Frequency range 169 4000 169 8125 MHz Channels 16 Channel spacing 25 kHz Maximum communication distance according to orography Om...

Page 5: ...each frame received from the master module with the status of its inputs and is reproduced on the outputs of the master module according to the established input output mapping There can be two securi...

Page 6: ...onstant short flashes Each module has three additional status LEDs at the bottom Yellow LED Steady indicates communication is established Green LED It will turn on whenever there is an active input Re...

Page 7: ...ctivated To facilitate the passage of the hose from the inputs and outputs of each module to the devices to be activated three cable glands have been placed in the boxes Antenna The standard system is...

Page 8: ...ave radio control where a digital sensor is connected to the radio control located in the reservoir which when insufficient water is detected contact closes sends an order to the radio control located...

Reviews: