CAUTION 

High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other 

combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear. 
 

WARNING:

 To reduce the risk of fire, do not store or

 

use gasoline or other flammable vapors and 

liquids in the vicinity of the heater.

 

 

INSTALLATION INSTRUCTION:

 

 

1.  Keep the unit at least 8 feet (2.4 m) away from the floor. This minimum distance must be 
maintained.  
2.  Do not install closer than1 foot (or 0.3 m) to any adjacent vertical surfaces or walls. 
3.  Keep at least 4.5 inches (11.5 cm) from the back wall (with or without using the wall hanging 
mounting bracket). 
4. Mark the drill-hole positions in the wall or ceiling for the mounting bracket.  
5.  Drill the required holes with diameter fit for the anchor provided for positioning the mounting 

bracket.  

6.  Insert the anchors.  
7.  Attach the mounting bracket to the wall or ceiling and secure with mounting screws.  

                                                                                                       
 
 
 
 
 
 
 
 
 
 
 
 
 
     
 
           

  WALL MOUNT                                              CEILING MOUNT 

8. Hook the unit to the mounting bracket and let the unit hang from the mounting bracket. 
9. Insert the screw through the mounting bracket and the heater handle, tighten the nut. 
 
 
 
 
 
 
 
 
 
 
 
                                                            
 
10. Loosen the screw to remove the wiring compartment/connection cover in the rear of the heater. 

 

Summary of Contents for PH-960

Page 1: ...1 6000W 240V CEILING MOUT WALL MOUNT GARAGE HEATER OWNER S MANUAL Model PH 960 IMPORTANT INSTRUCTIONS READ SAVE Technical Support 1 866 206 0888...

Page 2: ...2 TABLE OF CONTENTS Important Instructions 3 Specifications and Wiring Diagram 4 Parts of the heater 5 Installing Instructions 5 6 Operating Instructions 7 Maintenance and Cleaning 8 Troubleshooting 8...

Page 3: ...es or walls Keep at least 4 5 inches 11 5 cm from the back wall with or without using the wall hanging mounting bracket 9 Do not insert or allow foreign objects to enter any ventilation or exhaust ope...

Page 4: ...4 Wall Ceiling Mount Heater Model PH 960 Volt 240 V Watts 6000 W Frequency 60 Hz BTU h 20472 Recommended Heating Capacity 1 25 watts ft 0 03m Wiring diagram SPECIFICATIONS PH 960...

Page 5: ...l and local building codes All Wiring procedures and connections shall be in accordance with the national and local codes having jurisdiction Before installation Disconnect the main supply connection...

Page 6: ...urfaces or walls 3 Keep at least 4 5 inches 11 5 cm from the back wall with or without using the wall hanging mounting bracket 4 Mark the drill hole positions in the wall or ceiling for the mounting b...

Page 7: ...rn the thermostat to the farthest clockwise position The fan should start and the unit begins heating the room and lamp is light After the room reaches comfort level turn the thermostat counterclockwi...

Page 8: ...atically after 10 minutes If the thermal cut off protection trips again consult a certified electrician to determine the reason for overheating Problem Probable Cause Solution Unit is not heating Over...

Reviews: