Mount generator

1.  Remove the battery from the generator.
2.  Fit the generator in place on the Pro-B MainsDock.
3.  Ensure that the Locking Bracket [1] locks the generator in place.
4.  Connect the power cable to the Pro-B MainsDock and to AC mains power. The Power 

On Indicator [2] will be green, indicating that mains power is connected.

Dismount generator

1.  Disconnect the Pro-B MainsDock from AC mains power.
2.  The Power On Indicator [2] will remain green for a few seconds.
3.  Press down the Locking Bracket [1] and remove the generator.

Summary of Contents for Pro-B MainsDock

Page 1: ...Pro B MainsDock User s Guide...

Page 2: ...Pro B MainsDock 2 www profoto com...

Page 3: ...ance qualityandsafety Forthisreasonourflashequipmentiswidely usedinrentalstudiosandrentalhousesworldwide fromParis London Milan NewYork TokyotoCapeTown Some photographers can tell just from seeing a p...

Page 4: ...anges or modifications not expresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser sauthoritytooperatethe equipment Onlyapproved suppliedpowercordmaybeused WARNING Electrical Shock High Vo...

Page 5: ...ply 8 Over temperature protection 8 Locking Bracket 8 Generator features 9 Battery Indicator 9 Recycling time 9 Modeling light 9 Charger 9 Operating instructions 10 Mount generator 10 Dismount generat...

Page 6: ...he Pro BMainsDock ThePro BMainsDockiscompatiblewiththefollowingProfotogenerators Pro 7b Pro B2EOP2 updateneeded Pro B3serialnoabove1104180060 ATTENTION Pro B3 belowserialnumber1104180060 andthediscont...

Page 7: ...Pro B MainsDock 7 www profoto com Nomenclature 1 2 3 4 5 1 LockingBracket 2 PowerOnIndicator 3 OverTemperatureIndicator 4 Powersupply AC Connector 5 AirVent notvisibleinfigure...

Page 8: ...the generator is running under load for example during recycling Itisfullynormalthatthefangoesonandoff DonotblocktheAirVent 5 Should the temperature inside the generator become too high the Pro B Mai...

Page 9: ...er when used with the Pro B MainsDock compared to when the generator is powered from the battery The recycling timedependsontheenergysetting asspecifiedinsectionTechnicaldata Modelinglight Whenthegene...

Page 10: ...hattheLockingBracket 1 locksthegeneratorinplace 4 Connect the power cable to the Pro B MainsDock and toAC mains power The Power OnIndicator 2 willbegreen indicatingthatmainspowerisconnected Dismountge...

Page 11: ...ture Indicator 3 hasared lightandthegenerator isturnedoff ThePro BMainsDockhas automaticallyturnedoff thegeneratortoprotectit fromoverheating Waituntilthetemperature decreases ThePro B MainsDockwillau...

Page 12: ...0fps 9 4WsFAST 66ms 15fps 9 4WsNORMAL All data are to be considered as nominal and Profoto reserves the right make changes withoutfurthernotice Warranty AllProfotoproductsareindividuallytestedbeforeth...

Page 13: ...nforProfotoFlashGeneratotrs Pro 7b Pro B2andPro B3 Type ProfotoPro BMainsDock ProfotodeclaredthattheproductcomplieswiththeessentialrequirementsofLowVoltage Directive LVD 2006 95 ECandEMCDirective2004...

Page 14: ...Pro B MainsDock 14 www profoto com...

Page 15: ...Pro B MainsDock 15 www profoto com...

Page 16: ...ProfotoAB SWEDEN Phone 4684475300 info profoto com www profoto com 344033 1 181 1 Printed in Sweden Technical data and product information are subject to change without notice...

Reviews: