•  The built-in IR receiver senses the flash release as well as IR signals from most IR sync 

transmitters.

•  The Profoto Air radio system is fully integrated in the D1 Air units, allowing radio 

synchronization via a Profoto Air Remote or Profoto Air Sync device connected to the 
camera, or via the Profoto Air USB device connected to a computer with the Profoto 
Studio Air program.

•  D1 units without integrated Profoto Air functionality can be equipped with a Profoto Air 

Remote or Profoto Air Sync device acting as receiver, enabling radio synchronization 
via another Profoto Air Remote or Profoto Air Sync device connected to the camera.

ready signaling

Ready signaling is used to indicate when the unit is fully charged. The Ready Button [9a] 
is used to select one of four ready signaling alternatives:

•  BEEP: A clear “beep” will sound to indicate that the charging of the unit is completed. 

This setting also enables the control panel sounds, which indicates that a button is 
pressed or the Setting Knob is turned.

•  DIM: The modeling light will be turned off when the unit is being charged, and turned 

on again when the charging is completed. This setting also disables the control panel 
sounds.

•  BEEP-DIM: The modeling light will be turned off when the unit is being charged, and 

turned on again when the charging is completed. A clear “beep” will also sound to 
indicate that the charging is completed. This setting also enables the control panel 
sounds.

•  OFF: No ready signal. This setting also disables the control panel sounds.

ready indicator/Test function

The Ready Indicator [5] is illuminated when the unit is fully charged and ready to flash.

The Test Button [4] is used to test that all light settings are correct and that the functionality 
is as expected. When the Test Button [4] is pressed, the unit will flash and the Ready 
Indicator [5] will be turned off while recharging. When the charging of the unit is completed, 
the Ready Indicator [5] will be illuminated again.

flash before ready

The “Flash before ready” function makes it possible to flash before the charging of the unit 
is ready and fully completed. When a flash is released before the unit is 100% recharged, 
a long “beep” will sound, indicating an under exposed frame. Naturally the flash light may 
not correspond fully to the set value. 

Summary of Contents for D1 250

Page 1: ...D1 1000 Air D1 500 Air D1 250 Air D1 500 D1 250 User s Guide...

Page 2: ...Profoto D1 2 www profoto com...

Page 3: ...ty Forthisreasonourflashequipmentiswidelyusedin rentalstudiosandrentalhousesworldwide fromParis London Milan NewYork TokyotoCapeTown Some photographers can tell just from seeing a picture if Profotoeq...

Page 4: ...siderable time after being turned off Do not touch modeling lamp or flash tube when mounting umbrella metal shaftinitsreflectorhole Disconnectlampheadcablebetweengeneratorandlampheadwhenchanging model...

Page 5: ...r temperature 12 Reflector 12 Umbrella 12 Operating instructions 13 Stand mounting 13 Mounting of external reflector 13 Umbrella mounting 13 Glass cover mounting 13 Power connection 13 Energy level se...

Page 6: ...nimal stray light and maximal light output Itisdesignedforusewithsoftboxesandumbrellasandforusewithorwithoutadditional reflectors Short flash duration gives images a crisp feel and the fast recycling...

Page 7: ...enumberofD1units with thesamehighperformanceasProfotoAirRemote ProfotoAirUSB TheProfotoAirUSBdeviceisaUSB2 0transceiver whichconnectsyourD1Airunittoyour PCorMacviaawirelessconnection ProfotoAirUSBallo...

Page 8: ...erSupplyIndicator 4 TestButton 5 ReadyIndicator 6 ChannelSetButton 7 SettingKnob 8 SLAVESETTING 8a SlaveButton 8b RADIOIndicator 8c IRIndicator 9 READYSETTING 9a ReadyButton 9b BEEPIndicator 9c DIMInd...

Page 9: ...Profoto D1 9 www profoto com 12 13 14 15 16 17 18 12 SyncConnector 13 PowerSupply AC Connector 14 FuseHolder 15 UmbrellaTube ontheupperside 16 LockingKnob 17 ZoomScale 18 StandAdapter...

Page 10: ...werbeingcharged intotheunit Energycontrol The current energy level of the flash light is shown in the Display 1 in f stop scale The maximalenergy 100 isshownas10 The Setting Knob 7 is used to adjust t...

Page 11: ...ned DIM Themodelinglightwillbeturnedoffwhentheunitisbeingcharged andturned onagainwhenthechargingiscompleted Thissettingalsodisablesthecontrolpanel sounds BEEP DIM The modeling light will be turned of...

Page 12: ...tube a recommended color temperature for daylight type film Distinctive color temperatureadjustmentscanbeobtainedbyusingglasscoverswithdifferentcoatings Reflector D1 is equipped with a built in reflec...

Page 13: ...1 EnsurethattheD1unitisturnedoffandthatthepowercableisnotconnected 2 Iftheunithasbeeninuse waitfiveminutestoallowtheunittobefullydischarged the autodumpfunction 3 Gentlyremovethefrostedglassplate 4 Ca...

Page 14: ...modelinglight 3 WhiletheDisplay 1 isflashing usetheSettingKnob 7 tochangetheenergylevel a Turn the Setting Knob 7 clockwise to increase the energy level in 1 10 f stop incrementsandcounter clockwiseto...

Page 15: ...o channel has to be set on the D1 unit and the ProfotoAir deviceortheProfotoStudioAirprogram ForremotecontrolusingProfotoAirRemote thesameradiochannelandgrouphavetobe setontheD1unitandtheProfotoAirdev...

Page 16: ...e is removed the modeling light will revert to the default settings the modeling light will be turned off andtheenergylevelofthefreemodelinglightwillbesetto10 1 PresstheOnButton 2 toturnoffthepower 2...

Page 17: ...around the clasp Grasptheflashtubeinthebottomandpullitstraightoutofthesocket When inserting the new flash tube ensure that the trigger connection clasps properlyaroundtheflashtube Lock the flash tube...

Page 18: ...ted 2 Iftheunithasbeeninuse waitfiveminutestoallowtheunittobefullydischarged the autodumpfunction 3 PullouttheFuseHolder 14 fromtheunitandremovetheoldfuse 4 PushthenewfuseallthewayintotheFuseHolder On...

Page 19: ...ly After a while whenthetemperaturehasdecreasedsufficiently theunitwillstartrechargingata normalpace Thisautomaticprotectionwillonlyinterfereunderextremeconditions such aswhentheairventsareblocked Dep...

Page 20: ...durationt0 5min maxpower 1 700 1 1800 1 1000 1 2600 1 1400 1 3700 Recycling230V 0 2 2 0 0 2 0 95 0 2 0 65 Recycling120V 0 2 2 0 0 2 0 95 0 2 0 65 Colortemperature consistency K 30 30 30 Colortemperatu...

Page 21: ...ee Off Prop Free Synchronizationmodes Synccable IR Air Synccable IR Air Synccable IR Air Measurements Dimensionsmm length diameter 300x130 170includingStandAdapter Dimensionsinch length diameter 11 8x...

Page 22: ...This page is intentionally left blank...

Page 23: ...This page is intentionally left blank...

Page 24: ...ofotoAB P O Box2023 SE 12821Skarpn ck SWEDEN Phone 4684475300 info profoto com www profoto com 344091 1 320 Printed in Sweden Technical data and product information are subject to change without notic...

Reviews: