SPECIFICATIONS 

 

 
 

 

www.profort.com  

p. 

7

 

 
Power supply 

12-24V DC min 0,5 A (included) 

Battery 

3,6V rechargeable Li-ion battery (included) 

Consumption  

Approx. 35 mA while resting (supplied with 12VDC) 
150 mA when charging with battery 
2 mA in case of power failure and supply with battery 

Output  

Max 6 A at 230V AC 
Max 6 A at 35V DC 

Inputs, digital

 

Max 1V, 2 mA (GND) 

Input 0: also dis-/connection (level/pulse) 

Min. 18V max 30 V (24V DC) 

Input 1: also pulse/minute counter 

 

Input 2: also pulse counter  

Input, analogue 1 (AN 1) 

Profort temperature sensor (Profort-no. 007995) 

Input, analogue 2 (AN 2) 

0

-10V DC  

0/4-20mA 
PT-100 
Profort temperature sensor (Profort-no. 007995) 

Pulse and minute counter 

 

Max 10Hz. Max one mio. pulse or minutes 

Dimension 

Design box, black 
130x85x24 mm, weight: 125 g. 

Temperature 

– 20 °C - +55 °C 

Antenna 

1 internal antenna for GSM-modem. Possibility for external antenna (Profort-no. 369003) 
1 internal antenna for RF. Possibility for external antenna (Profort-no. 369003) 
 

The Profort PC Program Quick-setup 

Compatible with all versions of Windows. The PC needs to have a COM-port (RS232). A USB-RS232-
converter or connection through Internet via GRPS must be used. 
NB! Product key for the PC program is indicated on the cover of the CD.  

Other PC programs 

 

’Basis set-up’. Expands the set-up possibilities.  

 

’Professional set-up’ as an alarm central on PCs supplied with GSM-modem. 

Summary of Contents for multiGuard Technic RF

Page 1: ...ne short beep and then a red diode is lit After approximately 20 sec the diode flashes every 2 sec and the unit is ready 4 Connect a rechargeable 3 6 V Li ion battery The multiGuard unit interior DIP...

Page 2: ...choose a unique USERNAME You need the username to log on www profort com and or to activate the Internet access of the unit 3 Send following text messages to the unit Notice 1234 password Space counts...

Page 3: ...on input x by opening closing x 0 1 or 2 1234 Lx TEXT TEXT on input x by opening closing x 0 1 or 2 Delete 1234 Ax Deletes TEXT for input x by opening closing x 0 1 or 2 1234 Lx Deletes TEXT for input...

Page 4: ...rm on an input Outputs follow condition on inputs 1234 GA Indicates that the output follows the corresponding input if text is created Notice input signal has higher priority than command S0 S zero an...

Page 5: ...ower in percent 25 is lowest acceptable value yy battery status 1234 V1 R Downloads measurements on the analogue input Connection to the Internet 1234 EH USERNAME GPRS traffic starts 1234 EH GPRS traf...

Page 6: ...s in the same macro are divided by semicolon without space Example 1234 SHORT PULSE S0 B0 Play macro TEMP Plays the macro with the name TEMP Delete macro no 1 1234 M1 Deletes macro 1 M0 M9 For further...

Page 7: ...0V DC 0 4 20mA PT 100 Profort temperature sensor Profort no 007995 Pulse and minute counter Max 10Hz Max one mio pulse or minutes Dimension Design box black 130x85x24 mm weight 125 g Temperature 20 C...

Page 8: ...12 24 V power supply 9 V rechargeable back up battery acquisition Modbus interface IP 65 box Touch display for set up and programming multiGuard Remote IO 1 relay output 2 senders of infrared codes f...

Reviews: