Technical parameters

The type of the vacuum cleaner and the technical parameters 

are indicated on the rating label. Mains protection 16 A.

Does not cause interferences with audio/video devices.
Does not require grounding 

.

Profilo  vacuum  cleaners  meet  the  requirements  of  the 

applicable norms.

The appliance is in conformity with the requirements of the 

directives:

 

Electrical  equipment  designed  for  use  within  specific 

voltage limits (LVD) – 2006/95/EC.

 

Electromagnetic compatibility (EMC) – 2004/108/EC.

Noise level: 84 dB(A).

The appliance was marked by a   sign on the rating label.

Electrostatic charge

Vacuuming certain surfaces in low air humidity may lead to 

an electrostatic charge build-up. It is a natural phenomenon, 

which does not damage the appliance and is not a result of 

a fault.

In order to minimize electrostatic charge build-up:

 

discharge  the  appliance  by  frequently  touching  metal 

objects in the room with the suction tube,

 

increase the humidity in the room,

 

use widely available anti-static agents.

Features and components 

A

1

 Outlet filter cover

2

 Combination carpet & floor brush holder

3

 Power cord and plug

4

 Cord rewind button 

5

 Suction power adjustment slider

6

 “CYCLONE” dust container full indicator

7

 On/Off button 

8

 Vacuum cleaner cover release tabs

9

 Handle

10

 Suction hose

11

 Telescopic suction tube with hook attachment

12

 Outlet filter (fitted inside)

13

 Primary filter (E10 EPA) (fitted inside)

14

 Foam filter (fitted inside)

15

 “CYCLONE” dust container (removable accessory)

16

 Pre-filter cone (fitted inside)

17

 Combination carpet & floor brush

18

 Crevice nozzle

19

 Small brush

20

 Small nozzle

Prepare vacuum cleaner for operation 

B

1

 Insert  the  suction  hose  into  the  vacuum  cleaner  inlet. 

The distinctive click indicates a correctly mounted hose.

2

 Connect  the  other  end  of  the  hose  (handle)  with  the 

telescopic suction tube.

3

 Adjust  the  length  of  the  telescopic  suction  tube  as 

required using the slider as indicated by the arrow.

4

 Fit the appropriate nozzle or brush at the other end of the 

suction tube.

5

 Use  combination  carpet  &  floor  brush  for  vacuuming 

both hard surfaces and carpets. To vacuum hard surfaces — 

wood flooring, plastic floor lining, ceramic tiles etc. — extend 

the  brush  by  pressing  the  selector  switch  on  the  unit  as 

shown in Figure 

. Retract the brush when vacuuming 

carpets (set the selector switch to “

” position).

6

 Accessories  can  be  attached  to  the  accessory  holder 

located on the telescopic tube. Accessories are then readily 

accessible for use.

7

 Grab the plug and pull the power cord out of the vacuum 

cleaner.

 

  When  pulling  out  the  cord,  note  the  yellow 

stripe which marks the end of the cord. Further 

attempts to pull it out may cause damage.

8

 Plug in the appliance.

Before  turning  on  the  vacuum  cleaner  make  sure  that 

“CYCLONE”  dust  container,  primary  and  outlet  filters  are 

properly fitted in the appliance.

9

 Press the   on/off button to turn on the vacuum cleaner.

10

 The vacuum cleaner features a suction power regulator 

that allows continuous adjustment of the suction power. Adjust 

suction power using the suction power adjustment slider.

11

 Moving the slider as indicated will increase or decrease 

the suction power.

Remove filters

Make sure the appliance is turned off and unplugged from 

wall outlet before you replace the filters.

PRE-FILTER CONE

Periodically clean the pre-filter cone.

1

 Remove the “CYCLONE” dust container.

2

 Press  the  latch  located  on  the  “CYCLONE”  dust 

container and open the bottom of the container.

3

 Turn the pre-filter cone anti-clockwise (UNLOCK).

4

 Remove  the  pre-filter  cone  from  the  “CYCLONE”  dust 

container.

5

 If  the  pre-filter  cone  is  soiled,  you  can  rinse  it  under 

running water. Make sure the filter is dry before reinstalling.

 

  Note the seal on the bottom flange of the cone. 

Do not misplace it.

C

Summary of Contents for PSP322SK

Page 1: ...PA E10 lter easy to clean with running water 3 Bagless no need to buy bags which saves your money 4 Parking system easy storing PSP322SK PSP322SK 1 3 2 4 8 5 6 10 13 12 11 19 20 14 18 15 16 17 BSH Ev...

Page 2: ...ra size servis fi ini d zenleyip vermek zorundad r Bu servis fi ini mutlaka isteyiniz ve kesinlikle saklay n z BSH Ev Aletleri Sanayi ve Ticaret A Fatih Sultan Mehmet Mahallesi Balkan Caddesi No 51 34...

Page 3: ...mas n sa layan ayarlay c ya sahiptir G ayarlama s rg arac l yla ger ekle ir 11 S rg n n i aretlere g re kayd r lmas emi g c n y kseltir ya da d r r Filtrelerin s k lmesi Filtreleri de i tirmeden nce s...

Page 4: ...ir D IKI F LTRES 1 k filtresini de i tirmek i in k filtresinin kapa ndaki tutma yerlerini ekip k filtresinin kapa n s p rgeden kar n 2 k filtresini s p rgeden kar n 3 E er k filtresi kirlenirse akar s...

Page 5: ...iri filtresinin konisini ve hava filtresini de temizleyin S p rge so uyana kadar toz konteynerini takmay n Hortum borular emici u lar ve f r alar gibi aksesuar kontrol edip temizleyin S p rgeyi tekrar...

Page 6: ...he device and unplug it from an outlet before replacing the equipment or approaching moving parts during use Do not use the vacuum cleaner to clean people or animals pay special attention to keep the...

Page 7: ...t the other end of the hose handle with the telescopic suction tube 3 Adjust the length of the telescopic suction tube as required using the slider as indicated by the arrow 4 Fit the appropriate nozz...

Page 8: ...a damp outlet filter 4 Replace the filter cover so that the two tabs on the bottom of the cover fit the openings in the appliance body D E Press the filter cover so that the rear latches click into th...

Page 9: ...bes nozzles and brushes Reassemble the vacuum cleaner and turn it on If thermal protection is actuated too often or if after cooling the vacuum cleaner will not turn on take the vacuum to a service ce...

Page 10: ...yaz ma formunu doldurarak ya da 216 528 91 88 nolu telefona faks ekerek ula abilirsiniz A a da yer alan konulara zen g stermenizi nemle rica ederiz 1 Cihaz n z mutlaka kullanma k lavuzunda belirtilen...

Reviews: