After successful setting, user will receive a SMS reply with the content 
of “OK…”. If the SMS setting format is wrong, user will receive 
“FORMAT ERROR!”.

Note: 

V. Operation Instruction

1. Answer alarm call 

When there is an alarm, the ALARM LED on the panel will be on and 
the  external  siren  (if  user  has  connected)  will  ring  for  3  minutes  if 
there's  no  operation. Also  the  device  will  send  alarm  SMS  to  and  call 
the  preset  numbers.  Press  DISARM  button  on  the  main  panel  or  the 
remote controller, it will stop the alarm. 

The  alarm  system  will  keep  calling  all  the  preset  numbers  in  order  if 
nobody answers the call. The default circle time is 3. 

If  someone  answers  the  call,  it  will  enter  two-way  intercom  status 
automatically and the siren stops ringing. 

Then user can press “1#” to arm, 

                                  “2#” to disarm, 

                                  “3#” to listen-in, 

                                  “4#” to return to intercom.  

A  long  beep  means  correct  operation  and  three  short  beeps  means 
wrong operation.

Operation Instruction

5. Factory reset

Press the [RESET] button for 5 seconds until the LEDs on the panel are 
flashing  quickly.  After  this  operation,  all  the  settings  return  to  factory 
default.

2. Remote control  operation
Operation by remote call:

When users are outside and want to monitor the alarm system, he can 
call the alarm panel. After getting through the call, user will hear a long

Summary of Contents for yl-007eg Mobile Call

Page 1: ...DISARM STATUS POWER MONITOR ALARM SOS...

Page 2: ...status explanation 2 Host panel IV System Settings 1 Coding of wireless sensors 2 Exit coding 3 Settings by call 4 Settings by SMS V Operation Instruction VI Technical Parameters VII Standard Kit VII...

Page 3: ...he SMS content of the first 5 wireless sensors can be edited by users Support remote listen in and two way communication connect an external speaker SMS alert for power failure or recovery Built in ba...

Page 4: ...siren optional c Connect the two way intercom speaker optional d Connect wired sensors optional 3 Power Plug in the power adaptor and turn on the backup battery switch The LED indicator will flash and...

Page 5: ...SIM card and GSM signal are normal have stored numbers in SIM card in arm status Red In coding status wait to set sensors Green flash quickly Sensor is set successfully Red and Green flash alternatel...

Page 6: ...456 Operation password used for system settings Default 888888 System Settings GND Siren Siren Wired port 1 SPK Negative of two way intercom speaker black cable SPK Posi tive of two way intercom speak...

Page 7: ...will replace the coded one from No 1 2 Exit coding In coding status press RESET button again Or if there s no operation within 5 seconds after entering coding status it will exit coding automatically...

Page 8: ...ber Number should not exceed 20 digit Delete SMS number 55 59 Turn on power LED 00 1 Default on Turn off power LED 00 0 Power failure recovery alert 01 1 ON Default on 01 0 OFF Alarm call circle time...

Page 9: ...02 5 set the alarm call circle as 5 times All the following commands in Table 2 can also be set by SMS The SMS should begin with operation password The default password is 888888 Table 2 Change alarm...

Page 10: ...ll the preset numbers in order if nobody answers the call The default circle time is 3 If someone answers the call it will enter two way intercom status automatically and the siren stops ringing Then...

Page 11: ...there s no input within 30seconds after getting through the call it will also be hung up automatically Power DC12V 1 2A Status current 30mA GSM bands 850 900 1800 1900MHz Wireless receiving frequency...

Page 12: ...VIII Care and Maintenance 10...

Page 13: ...11...

Page 14: ...12...

Page 15: ...2012 07 V1 0...

Reviews: