1
PROFIBUS INTERFACE
PROFI232
rel. 53160501
Page 1: ...1 PROFIBUS INTERFACE PROFI232 rel 53160501 ...
Page 2: ...2 INDEX 1 MAIN TECHNICAL SPECIFICATIONS 3 2 DIMENSIONS 3 3 EARTHING MODULE 4 4 CONNECTION SCHEMES 4 ...
Page 3: ... board or 5Vdc on internal AMP connector ABSORPTION max 0 5 A SERIAL RS232 on terminal board and internal AMP connector FIELDBUS PROFIBUS DP female 9 pins connector CASE Plastic console suitable for mounting on DIN bar or on the wall BOARD DIMENSION 50x87mm 2 DIMENSIONS ...
Page 4: ... earth references of the connection and power supply cable of the indicator and of the connected instrument must be at the same potential GENERAL NOTES Use Earth plate of suitable length in order to obtain a total resistance of earthing plant lower than 1 Ω One should check and remove if necessary the connection between the earth and the neutral wire of the electrical installation 4 CONNECTION SCH...
Page 5: ...r 2 clamp and the GND on the 3 and 4 clamp RS232 SERIAL 5 TXD TX 6 RXD RX 7 GND GND EARTHING 8 9 ERTH EARTH Note the earth cable can be connected either on the 8 or 9 clamp Y2 AMP 1 RX 2 TX 4 5Vdc 6 GND J2 JUMPER INT if the power supply is supplied from the terminal board AMP if the power supply is supplied from the Y2 AMP connector MEANING OF DB9 PROFIBUS CONNECTOR Y1 ...