background image

Contents

  1. Introduction  ........................................................................................................................... 2

  2. In general  .............................................................................................................................. 2

  3. Ranges of application ............................................................................................................ 3

  4. Operation  .............................................................................................................................. 3

  5. Installation  ............................................................................................................................ 3

  6. Security tips............................................................................................................................ 4

  7. Servicing  ............................................................................................................................... 5

  8. Guarantee regulations ........................................................................................................... 5

  9. Recognising and repairing of mistakes  ................................................................................. 5

10. Notes on Product Liability  ..................................................................................................... 6

11. Notes on Disposal  ................................................................................................................. 6

12. EU Declaration of Conformity ................................................................................................ 6

13. Technical Data ..................................................................................................................... 12

14. Installation scheme  ............................................................................................................. 12

2. IN GENERAL

The pumps are developed according to the newest stand of technology, manufactured with 

much care and go under strict intensive controls. These pumps were optimised by us in particu-

lar for the special demands in dirty water areras. Make sure after unpacking the pump that the 

data given on the type label match with the included operating instructions. In case of doubt the 

pump is not to be used.

Transport damages are immediately to be reported to the package distributor and to us in writ-

ten form.

2 English

1. INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust. 

That‘s why funtional security and operational safety stands by us on first place.

  

To prevent damage to persons or property, you should read this user manual 

carefully. Please observe all safety precautions and instructions for proper use 

of the pump. Failure to follow the instructions and safety precautions can result 

in injury or property damage.

  Please keep this manual with the instructions and safety instructions carefully 

in order to at any time you can restore them. Please always download the latest 

version of the user manual of www.profi-pumpe.de under „downloads“. This 

shall always prevail.

SAFETY INSTRUCTION AND WARNINGS

Please read the user manual 

before using the device

Pull power plug

Warning sign

Warning of electrical voltage 

Summary of Contents for REGEN-STAR SUPER 750

Page 1: ...ts and mistakes reserved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de TAUCHPUMPE REGEN STAR 800 3 TAUCHPUMPE REGEN STAR SUPER 750 TAUCHPUMPE REGEN STAR SUPER 900 ...

Page 2: ...port damages are immediately to be reported to the package distributor and to us in writ ten form 2 English 1 INTRODUCTION We would like to congratulate you on the purchase of our pump We appreciate your trust That s why funtional security and operational safety stands by us on first place To prevent damage to persons or property you should read this user manual carefully Please observe all safety...

Page 3: ...ed The pump is to be secured through a RCD circuit breaker with release current of 30 mA Also it is NOT recommended to perform for example a cable extension It is not certain whether this modification is technically correct so this warranty is void It must be en sured that the pump is sufficiently cooled during prolonged operation It is not recommended to perform even cable extensions or other tec...

Page 4: ...o lack skills experience and knowledge only if they are supervised These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers l Cleaning and maintenance must not be carried out by children without supervision l The pump must not be used or operated under any circumstances when there are people in the same water l Under certain cirumstances ...

Page 5: ...ou how to proceed with case related Returns please sufficient postage Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery Our service we provide in Germany The warranty does not cover l Improper installation self installation unauthorized persons l Material wear sealing rings impeller wheels impeller chambers l Unjustified interventions or changes in...

Page 6: ...below the rele vant EU directives and harmonized corresponds to the EU standard for security This declaration is valid insofar as no changes to the product are made Authorized person to keep the technical documents 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Low Voltage Directive 2006 95 EC EC Electromagnetic compatibility directive 2004 108 EC The following harmonized standards EN...

Page 7: ...verzüglich dem Speditionsunternehmen und uns schriftlich mitzuteilen 1 VORWORT Zum Kauf unserer Pumpe möchten wir Sie recht herzlich beglückwünschen Wir wissen Ihr Vertrauen zu schätzen Aus diesem Grund stehen bei uns Funktions und Betriebssicherheit an erster Stelle Um Personen und Sachschäden zu vermeiden lesen Sie die vorliegende Bedie nungsanleitung bitte aufmerksam durch Bitte beachten Sie al...

Page 8: ...wässerung l Sonstige Klarwasserförderung 4 INBETRIEBNAHME Die Installation ist von einer qualifizierten Fachkraft auszuführen Bitte überprüfen Sie vor jeder Inbetriebnahme die elektrischen Anschlüsse sowie das Kabel auf Unversehrtheit Bitte prüfen Sie vor der Installation ob der elektrische Anschluss entsprechend der gesetz lichen Vorschriften geerdet und installiert ist Achten Sie darauf daß die ...

Page 9: ...ebrauchs des Gerätes unterwiesen worden sind und die daraus resultierenden Gefahren verstehen l Die Reinigung und Wartung darf nicht von Kindern ohne Beaufsichtigung durchgeführt werden l Die Pumpe darf unter keinen Umständen benutzt oder in Betrieb genommen werden wenn sich Personen im Wasser aufhalten l Unter Umständen ist es möglich daß eine Verschmutzung des Wassers durch Ausflie ßen von Schmi...

Page 10: ...a 2000 Stunden sollten die me chanischen Bauteile wie Laufräder Laufkammern Dichtungen etc auf Unversehrtheit hin überprüft und ggf getauscht werden Nach 3000 Betriebsstunden sollte ggf das Öl in der Kammer ausgetauscht werden nur bei ölgetauchten Motortypen Bitte nur bis zu 80 auffüllen und die Dichtungen stets auf Dichtigkeit überprüfen Bei abrasiven Materialien wie Sand verkürzt sich die Wartun...

Page 11: ...ern an dem Produkt keine Veränderungen vorgenommen werden Autorisierte Person zur Aufbewahrung der technischen Dokumente 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Richtlinie Niederspannung 2006 95 EG Richtlinie Elektromagnetische Verträglichkeit 2004 108 EG Folgende harmonisierte Normen EN 60335 1 2012 A11 2014 EN60335 2 41 2003 A2 2010 EN62233 2008 EN55014 1 2006 A2 2011 EN55014...

Page 12: ...Spannung 230V 50 Hz 230V 50 Hz 230V 50 Hz Measures in cm Maße in cm tba folgt tba folgt tba folgt Weight Gewicht ca 9 kg ca 16 kg ca 16 kg Pressure connection Druckanschluss G11 4 G1 G1 Cable length Kabellänge 10 m 25 m 25 m All products listet in this manual are Made in PRC Alle Produkte in dieser Bedienungsanleitung sind Made in VRC 14 INSTALLATION SCHEME INSTALLATIONS SCHEMA Panzerschlauch Flex...

Reviews: