Profi-pumpe QUELLBACH II DUNKEL-GRAU Operating Instructions Manual Download Page 5

8 English

Deutsch 9

10. noteS on ProduCt lIabIlIty 

We point out, that we are only liable for damages under the Product Liability Act, which are 

caused by our units if no changes were made to the equipment. If repairs are carried out by our 

authorized service, we are only liable if original spare parts and accessories were used.

11. noteS on dISPoSal

Electro devices of our company, labeled with the symbol of the crossed trash bin, are 

not permitted to be disposed in your household garbage. We are registered at the 

German registration department EAR under the 

Weee-no. de25523173.

 

This symbol means, that you’re not allowed to treat this product as a regular 

household waste item – it has to be disposed at a recycling collection point of electri-

cal devices. This is the best way to save and protect our earth.

thanK you For your SuPPort! 

12. eu deClaratIon oF ConFormIty

The products listed overleaf accordance with the marketed in accordance with the relevant 

provisions listed below, the relevant EU directives and harmonized with EU standards for safety. 

This declaration is valid insofar on the product, no changes are made.
Authorized person to keep the technical documents:

1A-Profi-Handels GmbH · Unterriethstraße 37 · D-65187 Wiesbaden

low Voltage directive (2014/35/eu)

EN61347-2-13:2014/A1:2017; EN61347-1:2015; EN62493:2015

eC electromagnetic compatibility directive (2014/30/eu)

The following harmonized standards:

EN 55032:2015; EN 55032:2012; EN 55020:2007/A12:2016; EN 55015:2013/A1:2015  

EN 55015:2013; EN 61547:2009; EN 55014-1:2006+A2:2011; EN 55014-2:2015

EN 55014-2:1997/A2:2008

EN 61000-3-2:2014; EN 61000-3-3:2013

Wiesbaden, 12th November 2017

ppa. Peter Neumüller

 

Problem

Possible cause

Solution

Pump will not 

turn on

Connector not inserted correctly

Check all cable connections

Defective pump or adapter

Replace pump or adapter

Pump runs but 

no water is 

encouraged

Pump impeller and filter housing 

polluted

Check water level, make sure the pump 

Is fully submerged In water.

Impeller blocked

Check the pump impeller blocked by 

debris

Possible kink or blocked hose

Check the fountain tubing for kinks and 

obstractions

Pump has sucked air

Turn off the pump briefly and then back on 

(restarting) Attention! Avoid dry running

Coarsining or fountain nozzles dirty Disassemble and clean the tube and the 

fountain nozzle

9. reCognISIng and rePaIrIng oF mIStaKeS

1. VorWort

Zum Kauf unserer Bachlaufs möchten wir Sie recht herzlich beglückwünschen. Wir wissen Ihr 

Vertrauen zu schätzen. Aus diesem Grund stehen bei uns Funktions- und Betriebssicherheit an 

erster Stelle.

um Personen- und Sachschäden zu vermeiden, lesen Sie die vorliegende bedie-

nungsanleitung bitte aufmerksam durch. bitte beachten Sie alle Sicherheitshinweise 

und anweisungen zum sachgemäßen gebrauch des bachlaufs. eine nichtbeachtung 

der anweisungen und Sicherheitshinweise können zu körperlichen Schäden oder zu 

Sachschäden führen.

bitte bewahren Sie die bedienungsanleitung mit den anweisungen und Sicherheits-

hinweisen sorgfältig auf, um jederzeit darauf zurückgreifen zu können.  

bitte laden Sie stets die neueste ausführung der bedienungsanleitung von  

www.profi-pumpe.de unter „download“ herunter. Diese ist stets maßgebend.

SICherheItShInWeISe und Warnungen

Bitte lesen Sie vor Inbetriebnahme der 

Pumpe die Bedienungsanleitung

Netzstecker ziehen

Allgemeines Warnzeichen

Warnung vor elektrischer Spannung

Inhaltsverzeichnis

  1.  Vorwort  ................................................................................................................................. 9

  2.  Allgemeines  ....................................................................................................................... 10

  3.  Bedienung  .......................................................................................................................... 10

  4.  Wartung  ............................................................................................................................. 12

  5.  Montageanleitung  .............................................................................................................. 12

  6.  Funktion  ..................................................................................................................................  13 

  7.  Sicherheitshinweise ............................................................................................................ 14

  8.  Garantiebestimmungen  ..................................................................................................... 14

  9.  Erkennen und Beheben von Fehlern  ................................................................................. 14

10.  Hinweise zur Produkthaftung  ............................................................................................. 15

11.  Entsorgungshinweise  ......................................................................................................... 15

12.  EU-Konformitätserklärung  ................................................................................................. 15

13.  Technische Daten  .............................................................................................................. 16 

14.  Erhältliches Zubehör und Ersatzteile  ................................................................................. 16

Summary of Contents for QUELLBACH II DUNKEL-GRAU

Page 1: ...reserved Newest information about our products can be found online Technische nderungen Druckfehler und Irrt mer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi...

Page 2: ...pc 4 way cable splitter 4pc LED lights 1 pc Hybrid solar panel sold separately l To protect the product place all parts on a flat soft surface 3 1 A regular linear water course can be formed as shown...

Page 3: ...ce the risk of fire or electrical shock DO NOT expose the power adapter to rain or moisture DO NOT short the polarity output cords and connectors l DO NOT use It if you find anything damaged to its ho...

Page 4: ...attention to the medium temperature max 35 C l The mains plug must be disconnected before carrying out any work on the water course l Never pull the pump on the electrical cable or pressure hose l Avo...

Page 5: ...cable connections Defective pump or adapter Replace pump or adapter Pump runs but no water is encouraged Pump impeller and filter housing polluted Check water level make sure the pump Is fully submerg...

Page 6: ...en Steckern feststellen l Verwenden Sie das Netzteil Nicht mit anderen Ger ten als dem speziell daf r vorgesehenen Produkt l Dieses Ger t darf von Kindern ab 8 Jahren sowie von Personen mit verringert...

Page 7: ...in den Boden ein Positionieren Sie das Panel so weit wie m glich nach S den in der n rdlichen Hemisph re um die Tageslichtstunden optimal zu nutzen Es ist wichtig das Solarpanel in die Sonne zu stell...

Page 8: ...men wir den Umtausch oder die Reparatur der Pumpe Versandkosten werden von uns nur getragen soweit dies gesetzlich vorgeschrieben ist Im Garantiefall bitte ber unsere Serviceplattform http www profi...

Page 9: ...sse IP44 IP44 Adapter Input Einspeisung 100 240V 50Hz 100 240V 50Hz Output Ausgangsleistung 8 5V 3Watt 8 5V 3Watt Protection grade Schutzklasse IP44 IP44 LED Quantity Anzahl 4x5LEDs 4x5LEDs Colour Far...

Reviews: