4 English
l
By pressing the “ “ or “
“ key, the setpoint value of the working pressure can be set; a
short press of the “ “ key increases the pressure by 0.1 bar each time. A short press of the “
“ button reduces the pressure by 0.1 bar each, holding the buttons causes the pressure to
rise or fall quickly.
l
Open the water tap after setting the pressure, the control system regulates the pump accor-
ding to the water demand. Check that the pump is running normally and that the pressure
shown on the display is constant. If this is the case, the installation is complete. If you notice
any irregularities, please read the point
10. RECOGNISING AND REPAIRING OF
MISTAKES
.
6. BUTTONS AND FUNCTIONAL DISCRIPTION
Key function and display description
NO.
NAME
DESCRIPTION
1
Rotor Icon
The rotor icon rotates while pumping.
2 Performance bar One bar corresponds to 10% of the power.
3
Online Icon
Appears as soon as more than two pumps are working.
4
Lock icon
Pressure or speed control is blocked.
5
Bluetooth
Not applicable.
6
WiFi
Not applicable.
7
Current value
Shows the current pressure value in bar.
The pump stops at 0.0 bar.
8
Auto-Mode
Automatic constant voltage control mode.
9
Manu-Mode
Manual speed control mode.
10
Set value
Displays the manually set pressure value.
The factory default value is 3 bar.
11 Temperature unit Lights up when querying temperature.
12
Speed unit
Wird im manuellen Modus angezeigt.
13
Pressure unit
Wird im automatischen Modus angezeigt.
14
Fault icon
Leuchtet mit dem entsprechenden Fehlercode auf.
15 Increase button
Pressing the key increases the pressure by 0.1 bar
each time, holding the key down causes the pressure to
increase rapidly.
16 Decrease button
Pressing the key descrease the pressure by 0.1 bar at a
time, holding the key down causes the pressure to drop
rapidly.
17
STOP button
Switches the pump off.
18
RUN button
Starts the pump in manual or automatic mode (with
constant pressure).