4 English

IMPORTANT!

Problem

: Uneven water flow or splashes on the glass pane.

Correction

: During operation, an uneven flow of water over the pane may occur. In such cases, 

we recommend cleaning the glass pane with a grease solvent. This usually ensures even water 

flow without splashes.

4.1 Frost

Frost can cause damage to the pump. The pump must be removed and stored in 

a frost proof environment if the water is likely to freeze.

4. MAINTENANCE:

l

  Keep the fountain in good working condition by cleaning it and changing the water every  

3 days. Using distilled or purified water will give the best performance.

l

  If debris is caught in the intake vents of the pump, disconnect the pump from any power  

sources and rinse the pump under clean running water.

l

  Before storing the pump in winter it is absolutely important to rinse it with clean water. Any

   dirt particles remaining in the pump will dry out on the pump shaft during the time of 

   storage and cause irreparable damage.

5. SECURITY TIPS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping inflammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

  The mains plug must be disconnected before carrying out any work on the garden fountain

 

l

 Never pull the pump on the electrical cable or pressure hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size

 

l

 Don‘t add any additions into the water which could attack the material of the pump

 

l

  During longer unused times, clean the pump, wash it out with clear water, dry and store it 

at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

  The pump may be used by children aged 8 years and above as well as persons with 

reduced physical, sensory or mental abilities or those who lack skills, experience and 

knowledge only if they are supervised. These aforementioned persons should only use 

the appliance while adhering to safe instructions and resulting dangers.

 

l

  Cleaning and maintenance must not be carried out by children without supervision.

Summary of Contents for GB021110-4

Page 1: ...nformationen zu unseren Produkten finden Sie auf https www profi pumpe de de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG GARDEN FOUNTAIN with LED light GARTENBRUNNEN mit LED Licht Version 20 12 1 0 STE...

Page 2: ...ull power plug Warning sign Warning of electrical voltage 2 IN GENERAL The Garden fountains are high quality fountain pump systems for outdoor or indoor use The perfect eye catcher 2 1 It s recommende...

Page 3: ...pter l Fill clean water to the reservoir Note Destilled water is recomended to reduce mineral deposits and bacteria build up l Insert the plug into the power socket If installed correctly water will s...

Page 4: ...cause irreparable damage 5 SECURITY TIPS l Obey absolutely valid regulations on the electrical security l Never run pump dry l Pumping inflammable as well as all other aggressive liquids is prohibite...

Page 5: ...over we give no damage compensation for secondary damages 7 RECOGNISING AND REPAIRING OF MISTAKES Problem Possible cause Solution Pump does not start No electricity Check electrical connections Defect...

Page 6: ...the relevant regulations below the rele vant EU directives and harmonized corresponds to the EU standard for security This declaration is valid insofar as no changes to the product are made Low Volta...

Page 7: ...g auf um jederzeit darauf zur ckgreifen zu k nnen Bitte laden Sie stets die neueste Ausf hrung der Bedienungsanleitung von www profi pumpe de unter download herunter Diese ist stets ma gebend SICHERHE...

Page 8: ...F llen Sie sauberes Wasser in den Beh lter Hinweis Es wird destilliertes Wasser empfohlen um Mineralablagerungen und Bakterienbil dung zu reduzieren l Netzteil in die Steckdose stecken Bei korrekter...

Page 9: ...en Bei Frostgefahr muss die Pumpe entleert werden mit klarem Wasser gesp lt und trocken eingelagert werden 5 SICHERHEITSHINWEISE l Unbedingt geltende Vorschriften zur elektrischen Sicherheit befolgen...

Page 10: ...unsachgem em Betrieb l TROCKENLAUF auch testweise der Pumpe Au erdem leisten wir keinerlei Schadensersatz f r Folgesch den Problem M gliche Ursache L sung Pumpe l uft nicht an Kein Strom Elektr Ansch...

Page 11: ...ef hrten einschl gigen Bestimmungen den entsprechenden EU harmonisierten Richtlinien und dem EU Standard f r Sicherheit entsprechen Diese Konformit tserkl rung gilt insofern an dem Produkt keine Ver n...

Page 12: ...ment of the water flow The most common types of regulators are listed below please note the symole on the pump WASSERMENGEN REGLER Unsere Gartenbrunnen werden je nach Gr e mit verschieden Pumpen ausge...

Page 13: ...13 Notes Notizen...

Page 14: ...sion LxWxH Ma e LxBxH 34x34x64 cm 56x36x110 cm 36x31x70 5 cm Total weight Gesamtgewicht ca 5 kg ca 11 kg ca 8 kg English Deutsch SWEETHEART WASSER ZWILING KUGEL FANTASIE Adapter Voltage Spannung 230 V...

Page 15: ...600 l h Max pump height Max F rderh he 110 cm Max water temperature Max Wassertemperatur 35 C Length of cable Kabell nge 5 m Protective class Schutzklasse IP68 LED LEDs LEDs 1x12 Length of cable Kabel...