CONTENTS
1. Introduction .......................................................................................................................... 2
2. In general ............................................................................................................................. 2
3. Ranges of application .......................................................................................................... 2
4. Operation ............................................................................................................................. 3
5. Security tips .......................................................................................................................... 4
6. Servicing .............................................................................................................................. 5
7. Guarantee regulations ......................................................................................................... 5
8. Recognising and repairing of mistakes ................................................................................ 5
9. Notes on Product Liability .................................................................................................... 6
10. Notes on Disposal ............................................................................................................... 6
11. EU Declaration of Conformity .............................................................................................. 6
12. Technical Data ................................................................................................................... 12
4. OPERATION
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not
damaged. Also, it is NOT recommended to perform, for example, a cable extension. It
is not certain whether this modification is technically correct, so this warranty is void. It
must be ensured that the pump is sufficiently cooled during prolonged operation.
Diesel pumps are electrical products, which have to be protected against outer influences, f.e.
caused by weather. Only use the pump in well-ventilated rooms and areas with enough fresh
air. The floor, on which the pump may be used, should be flat. Please keep enough space from
walls. Place the diesel-tank as near to the pump as possible.
The specified suction lift is the maximum suction at optimal conditions. The suction line to the
pump has to be steadily increasing.
The pump and the suction pipe must be filled with
diesel/fuel oil before turning „on“ the pump.
Do not reduce the cross area of suction and
discharge lines. Connect suction and discharge lines to the pump by means of reinforced metal
hose. For stationary use please place the pump on rubber pads to reduce vibration transmissi-
on to and from the pump and thereby prevent damage caused. The suction and discharge line
should be connected to to the pump in souch way, that no mechanical stress on the connections
occure. For example, Fix lines by pipe clamps with rubber insert on the wall.
CAUTION: Do not connect a hose more than 5m to 1 inch on the pressure side. For smal-
ler hose diameters, use corresponding short hoses. When using a pump nozzle, it is ab-
solutely necessary to ensure that the pump is switched off immediately after the nozzle
is closed. These measures must be adhered to in order
to avoid damage of pumps.
Please read the user manual before
using the pump
Warning sign
Warning of electrical voltage
Pull power plug
Protective gloves
Protect from rain and moisture
SAFETy INSTRUCTION AND WARNINGS
3. RANGES OF APPLICATION
These pumps are made for pumping diesel or fuel oil ONLY!
IMPORTANT!
They are not suitable for pumping ignitable liquids like gasoline, kerosene, or for pumping at
places where the danger of an explosion exists. When using the pump, make sure there are no
open flames, lighters, matches, cigarettes or similar things present around you. When operating
suitable protective gloves must be worn.
These pumps are made for pumping clean diesel / biodiesel or fuel oil ONLY! The pumped liquid
should not contain abrasive components. Abrasive components reduces pump life.
2 English
English 3
1. INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust.
That‘s why funtional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper use
of the pump. Failure to follow the instructions and safety precautions can result
in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully
in order to at any time you can restore them. Please always download the latest
version of the user manual of www.profi-pumpe.de under „downloads“. This
shall always prevail.
2. IN GENERAL
The pumps in this are developed according to the newest stand of technology, manufactured
with much care and go under strict intensive controls.
The pumps were optimised by us in particular for their special demands. Make sure after unpa-
cking the pump that the data given on the type label agree with the included operating instruc-
tions. In the case of doubt the pump is not to be used. Transport damages are immediately to be
reported to the package distributor and to us in witten form.
Schematic represen-
tation as application
example. Please refer to
the quotation description
for the scope of delivery.