Technical data
Maintenance
Application
Display
Automatic Power OFF
Changing the battery
Function check
Measuring principle
Electrical resistance
Electrode length
8 mm
Electrodes
Integrated, replaceable
Measuring range
Wood: 1 – 45 %
Building material: 0.1– 2.4 %
Resolution
Wood: ±1 %
Material: ±0.1 %
Accuracy
±3. 0%RH
Auto power OFF
After approx. 15 minutes
Battery
3
×
Cr 2032, replaceable
Housing material
Impact-proof plastic housing
Ambient temperature
0 - 40°C
Ambient Relative humidity
0 – 85 %RH
Dimensions
139
×
47
×
25 mm
Weight
approximately 100g
Warranty
1 year
ŏ
Always keep instrument dry.
ŏ
Prevent dirt from getting in between the measuring electrodes.
ŏ
Changing the electrodes:
Unscrew the 5 screws at the back of the instruments.
Remove housing lid. Unscrew all 5 screws on the electronic plate. Replace
electrodes.
Close instrument again.
“O------
T
------O”
Connect electrodes with
T
contacts to the protective cap.
Reference display for wood: 27%±2%
Reference display for building material: 1.3%±0.1%
“ O------
B
------O”
Connect electrodes with
B
contacts to the protective cap.
Reference display for wood: 44%±2%
Reference display for building material: 2.1%±0.1%
Function error: Send instrument for servicing.
ŏ
Remove the cap from the top side and place on the bottom side. Push
the wood/building switch to the left side during wood measurement, and
building material measurement, push it to the right side.
ŏ
Press the measuring electrodes as far as possible into the material.
ŏ
Always measure the moisture in the wood perpendicular to the fibre
structure.
ŏ
Repeated measuring yields representative measured data.
ŏ
Once the measurement is finished, reattach the cap on the top side and
the instrument switches itself o
ff
.
The reading is shown in the form of data and bar gragh:
a continuous line
= even values e.g. 1, 3, 5,7,9
dotted line
= uneven values e.g. 0.2, 0.4, 0.6, 0.8, 1.0
Overflow: reading >45%/4.5%
Reference bar display has to full.
When the digital reading > 60%/6.0%, the LCD will display “OL”
Please note:
Characteristics due to growth or type of wood and deviating
wood temperatures may make it necessary to correct the displayed values.
Measurements should be carried out according to the drying and weighing/
calcium carbide method in the case of inspections or for reference
purposes.
In order to conserve battery life, the meter will automatically turn o
ff
after
approximately 15 minutes. To press and restoration the power switches the
meter display is on.
When the batteries become exhausted or drop below the operating voltage,
the battery warning “
” symbol will appear in the LCD display. The
battery should be replaced.
Unscrew the 1 screws at the back of the instrument.
Remove the battery housing. Change battery.
Observe polarization!
Reconnect instrument.