![PROF 502212370 Instruction Manual Download Page 3](http://html1.mh-extra.com/html/prof/502212370/502212370_instruction-manual_1610129003.webp)
2
3
Continuity test
Diode test
μ
micro (amps)
m
milli (volts, amps)
K
kilo (ohms)
CONTROLS AND JACKS
1. LCD Display
2. Function switch
3. 10A jack
4. COM jack
5. Positive jack
6. Data Hold Button
7. Backlight Button
Note:
Tilt stand, fuse and battery
compartment are on rear of unit.
SAFETY SYMBOLS
This symbol adjacent to another symbol, terminal or operating
device indicates that the operator must refer to an explanation
in the Operating Instructions to avoid personal injury or damage
to the meter.
WARNING
This WARNING symbol indicates a potentially hazardous
situation, which if not avoided, could result in death or serious
injury.
CAUTION
This CAUTION symbol indicates a potentially hazardous
situation, which if not avoided, may result damage to the
product.
This symbol advises the user that the terminal(s) so marked
must not be connected to a circuit point at which the voltage
with respect to earth ground exceeds (in this case) 500 VAC or
VDC.
This symbol adjacent to one or more terminals identifies them
as being associated with ranges that may, in normal use, be
subjected to particularly hazardous voltages. For maximum
safety, the meter and its test leads should not be handled when
these terminals are energized.
This symbol indicates that a device is protected throughout by
double insulation or reinforced insulation.
1
6
2
3
4
5
7
SYMBOLS AND ANNUNCIATORS
Ω
Ohms
VDC
volts direct current
VAC
volts alternating current
ADC
amps direct current
BAT
Battery test
SPECIFICATIONS
Function
Range
Resolution
Accuracy
DC Voltage
(V DC)
200mV
0.1mV
±(0.5% r 2 digits)
2000mV
1mV
20V
0.01V
200V
0.1V
±(0.8% r 2 digits)
600V
1V
AC Voltage
(V AC)
200V
0.1V
±(1.2% r 10 digits)
(50/60Hz)
600V
1V
DC Current
(A DC)
2000
μ
A
1
μ
A
±(1.0% r 2 digits)
20mA
10
μ
A
200mA
100
μ
A
±(1.2% r 2 digits)
10A
10mA
±(2.0% r 2 digits)
Resistance
200
Ω
0.1
Ω
±(0.8% r 2 digits)
2000
Ω
1
Ω
20k
Ω
0.01k
Ω
200k
Ω
0.1k
Ω
2000k
Ω
1k
Ω
±(1.0% r 2 digits)
Battery Test
9V
10mV
±(1.0% r 2 digits)
1.5V
1mV
NOTE:
Accuracy specifications consist of two elements:
ŏ
(% reading) – This is the accuracy of the measurement circuit.
ŏ
(+ digits) – This is the accuracy of the analog to digital converter.
NOTE:
Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75%