AC
POWER
Before operation ensure that factory setting of voltage and frequency match local power supply.
Always ground (earth) the fixture electrically.
Use only a source of AC power that complies with local building and electrical codes and has both
overload and ground-fault protection.
If it is necessary to substitute power supply plug, connect it in accordance with the following code:
GREEN/YELLOW: Ground
BLUE:
Neutral
BROWN:
Live
WARNING: the luminaire must be earthed
Connect the mains power cable to the fixture at the 3-prong IEC male input socket at the rear of the
fixture.
OVERHEAD
MOUNTING
-
PLLED155 is designed to be hung overhead with a clamp (not included).
-
Warning! Block access below the work area before proceeding.
-
Always use a secure means of secondary attachment (safety rope).
-
Verify that the structure can support at least 10 times the weight of all installed fixtures, clamps,
cables, auxiliary equipment, and other items.
-
If hanging the fixture with a rigging clamp, verify that the clamp is undamaged and is designed for
the fixture’s weight. Bolt the clamp securely to the mounting bracket on the fixture with a grade 8.8
(minimum) M12 bolt and lock nut, or as recommended by the clamp manufacturer, through the
clamp hole in the mounting bracket.
-
If permanently installing the fixture, verify that the hardware (not included) and mounting surface
can bear at least 10 times the fixture’s weight.
-
Working from a stable platform, clamp or fasten the fixture to the structure.
-
Install a safety cable that can hold at least 10 times the weight of the fixture through the safety cable
attachment point on the fixture.
-
Loosen the swivel locks, tilt the fixture to the desired angle, and retighten.
-
Verify that the fixture is at least 1 meter from any flammable surfaces.
-
Verify that the clearance around the air vents is at least 0.1 meters.