background image

 

 

2

 

IMPORTANT SAFETY INSTRUCTIONS 

Watch for these symbols: 

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the 

presence of uninsulated “dangerous voltage” within the product’s enclosure, that may be of sufficient magnitude to 

constitute a risk of electric shock to persons. 

 

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in the literature accompanying the appliance. 

 

1.

 

Read these instructions. 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with 

one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade 

or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an 

electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and 

the point where they exit from the apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

 

12.

 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 

apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury 

from tip-over. 

 

13.

 

Unplug this apparatus during lightning storms or when unused for long periods of time. 

14.

 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged 

in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the 

apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been 

dropped. 

15.

 

Warning: to reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 

16.

 

Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as 

vases, are placed on the equipment. 

17.

 

To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac 

receptacle. 

18.

 

The mains plug of the power supply cord shall remain readily operable. 

19.

 

This apparatus contains potentially lethal voltages. To prevent electric shock or hazard, do not remove the 

chassis, input module or ac input covers. No user serviceable parts inside. Refer servicing to qualified service 

personnel. 

20.

 

This owner’s manual should be considered as a part of the product, it must accompany it at all times, and it 

needs to be delivered to the new user when this product is sold. In this way the new owner will be aware of all 

the installation, operating and safety instructions. 

21.

 

This apparatus should only be connected to a power source of type specified in this owner’s manual or on the 

unit. 

22.

 

You can clean the exterior of the unit with compressed air or with a dry cloth. 

23.

 

Don’t clean the unit using solvents like trichloroethylene, thinners, alcohol, or other volatile or flammable 

fluids. 

24.

 

To reduce the risk, close supervision is necessary when the product is used near children. 

 

Summary of Contents for PA BMT MIC BASE

Page 1: ...BMT Base microfonica Microphone Call Station USER S MANUAL MANUALE D USO ENGLISH ITALIANO 96MAN0165 REV 4 22 ...

Page 2: ...d use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the ...

Page 3: ...product must be installed by qualified personal Please contact the manufacturer for further information PACKAGING SHIPPING AND COMPLAINT This unit package has been submitted to ISTA 1A integrity tests We suggest you control the unit conditions immediately after unpacking it If any damage is found immediately advise the dealer Keep all unit packaging parts to allow inspection Proel is not responsib...

Page 4: ...ONIC EQUIPMENT 3 DECLARATION OF CONFORMITY 3 CONDITIONS OF USE 3 PACKAGING SHIPPING AND COMPLAINT 3 WARRANTY AND PRODUCTS RETURN 3 INTRODUCTION 5 DESCRIPTION 5 MAIN FUNCTIONS 5 1 MIC INPUT 5 2 MIC OUTPUT 5 3 TALK LED 6 4 TALK BUTTON 6 INSTALLATION 6 TECHNICAL SPECIFICATION 6 ...

Page 5: ... without light ring Suggested models are PA MG400 cardioid 400 500mm length and PA MG400 cardioid 300 400 500mm length The MIC XLR input is wired as follows Pin 1 shield or ground Pin 2 positive or hot Pin 3 negative or cold This connector has a latch lock press it to release the gooseneck microphone 2 MIC OUTPUT XLR 3 male connector for microphone output and phantom power supply This connector al...

Page 6: ...lick when you enter it see illustration 2 Connect the call station microphone to the PA amplifier with an XLR shielded cable 3 Turn on phantom power on the PA amplifier for the microphone input being used 4 By pressing the TALK BUTTON on the microphone the LED turns on and you can make announcements 5 To remove the gooseneck microphone hold firmly the base push the latch lock see figure and extrac...

Page 7: ...ovute al ribaltamento 13 Scollegare questo apparecchio durante i temporali o se non viene utilizzato per lunghi periodi di tempo 14 Per tutte le riparazioni rivolgersi a personale qualificato La manutenzione è necessaria quando l apparecchio è stato danneggiato in qualche modo se il cavo o la spina di alimentazione sono danneggiati se è stato versato del liquido o se sono caduti oggetti nell appar...

Page 8: ...i vigenti Il prodotto deve essere installato da personale qualificato Si prega di contattare il produttore per ulteriori informazioni IMBALLAGGIO TRASPORTO E RECLAMI L imballo è stato sottoposto a test di integrità secondo la procedura ISTA 1A Si raccomanda di controllare il prodotto subito dopo l apertura dell imballo Se vengono riscontrati danni informare immediatamente il rivenditore Conservare...

Page 9: ...RICHE ED ELETTRONICHE 8 DICHIARAZIONE DI CONFORMITÀ 8 CONDIZIONI DI UTILIZZO 8 IMBALLAGGIO TRASPORTO E RECLAMI 8 GARANZIE E RESI 8 INTRODUZIONE 10 DESCRIZIONE 10 FUNZIONI PRINCIPALI 10 1 INGRESSO MIC 10 2 USCITA MIC 10 3 TALK LED 11 4 PULSANTE TALK 11 INSTALLAZIONE 11 SPECIFICHE TECNICHE 11 ...

Page 10: ...lunghezza 400 500mm and PA MG400 cardioide lunghezza 300 400 500mm L ingresso MIC XLR è cablato come segue Pin 1 schermo or massa Pin 2 positivo o hot Pin 3 negativo o cold Questo connettore ha un blocco a scatto premilo per rilasciare il microfono a collo d oca 2 USCITA MIC Connettore XLR 3 maschio per uscita microfono e alimentazione phantom Questo connettore permette di inviare il segnale audio...

Page 11: ...ofono della postazione annunci all amplificatore PA con un cavo XLR schermato 3 Attivare l alimentazione phantom sull amplificatore PA per l ingresso del microfono utilizzato 4 Premendo il pulsante TALK sul microfono il LED si accende ed è possibile effettuare annunci 5 Per scollegare il microfono a collo d oca tenere saldamente il supporto abbassare il fermo di blocco vedi figura ed estrarre il m...

Page 12: ...12 PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Reviews: