background image

FCC COMPLIANCE NOTICE

This device complies with part 15 of the FCC rules. Opera  on is subject to the following two condi  ons: 
(1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that may cause undesired opera  on.

CAUTION: Changes or modi

fi

 ca  ons not expressly approved by the party responsible for compliance could void 

the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protec  on against harmful interference in 
a residen  al installa  on. This equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and used in accordance with the instruc  on manual, may cause harmful interference to radio communica  ons. 
However, there is no guarantee that interference will not occur in a par  cular installa  on. If this equipment does 
cause harmful interference to radio or television recep  on, which can be determined by turning the equipment o

  

and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separa  on between the equipment and receiver.
• Connect the equipment into an outlet on a circuit di

 erent from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of 
its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this 
from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should 
contact either the retailer where they purchased this product, or their local government o

  ce, for details of where and how they can 

take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and condi  ons of the 

purchase contract. This product should not be mixed with other commercial wastes for disposal.

The lightning 

fl

 ash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated 

“dangerous voltage” within the product’s enclosure, that may be of su

  cient magnitude to cons  tute a risk of electric shock to persons.

The exclama  on point within an equilateral triangle is intended to alert the user to the presence of important opera  ng and maintenance 
(servicing) instruc  ons in the literature accompanying the appliance.

The informa  on contained in this publica  on has been carefully prepared and checked. However no responsibility will be taken for any errors. All 
rights are reserved and this document cannot be copied, photocopied or reproduced in part or completely without wri  en consent being obtained 
in advance from PROEL. PROEL reserves the right to make any aesthe  c, func  onal or design modi

fi

 ca  on to any of its products without any prior 

no  ce. PROEL assumes no responsibility for the use or applica  on of the products or circuits described herein.

Il marchio riportato sul prodo  o o sulla documentazione indica che il prodo  o non deve essere smal  to con altri ri

fi

 u   domes  ci al 

termine del ciclo di vita. Per evitare eventuali danni all’ambiente si invita l’utente a separare questo prodo  o da altri   pi di ri

fi

 u   e di 

riciclarlo in maniera responsabile per favorire il riu  lizzo sostenibile delle risorse materiali. Gli uten   domes  ci sono invita   a conta  are 
il rivenditore presso il quale è stato acquistato il prodo  o o l’u

  cio locale preposto per tu  e le informazioni rela  ve alla raccolta 

di

 erenziata e al riciclaggio per questo   po di prodo  o. Gli uten   aziendali sono invita   a conta  are il proprio fornitore e veri

fi

 care i 

termini e le condizioni del contra  o di acquisto. Questo prodo  o non deve essere smal  to unitamente ad altri ri

fi

 u   commerciali.

Il simbolo del lampo con freccia in un triangolo equilatero intende avver  re l'u  lizzatore per la presenza di "tensioni pericolose" non isolate 
all'interno dell'involucro del prodo  o, che possono avere una intensità su

  ciente a cos  tuire rischio di scossa ele  rica alle persone.

Il punto esclama  vo in un triangolo equilatero intende avver  re l'u  lizzatore per la presenza di importan   istruzioni per l'u  lizzo e la 
manutenzione nella documentazione che accompagna il prodo  o.

Le informazioni contenute in questo documento sono state a  entamente reda  e e controllate. Tu  avia non è assunta alcuna responsabilità per 
eventuali inesa  ezze. Tu    i diri    sono riserva   e questo documento non può essere copiato, fotocopiato, riprodo  o per intero o in parte senza 
previo consenso scri  o della PROEL. PROEL si riserva il diri  o di apportare senza preavviso cambiamen   e modi

fi

 che este  che, funzionali o di 

design a ciascun proprio prodo  o. PROEL non assume alcuna responsabilità sull’uso o sull’applicazione dei prodo    o dei circui   qui descri   .

Summary of Contents for LT812A

Page 1: ...LT812A ac ve loudspeaker system USER MANUAL MANUALE D USO ...

Page 2: ...may be of sufficient magnitude to cons tute a risk of electric shock to persons The exclama on point within an equilateral triangle is intended to alert the user to the presence of important opera ng and maintenance servicing instruc ons in the literature accompanying the appliance The informa on contained in this publica on has been carefully prepared and checked However no responsibility will be t...

Page 3: ...I GENERALI 14 ISTRUZIONI FIG 1 2 3 14 MODEL LT812A LT812SAT LT812SUB System type 2 way vented enclosure vented sub woofer High Frequency Device 1 compression driver 1 VC Low Frequency Device 8 woofer with 1 5 VC 12 woofer with 3 VC Angular Coverage 60 H x 40 V Max SPL at 1mt peak 121 dBspl 124 dBspl Crossover Frequency 2400 Hz 160 Hz Total peak power 1600 W Amplifier Con nuous Power SAT 2x 200 W C...

Page 4: ... 10k 5k 2k 1k 500 200 100 50 40 20k Hz 120 0 dBSPL 110 0 100 0 90 0 80 0 70 0 DIMENSIONS DIMENSIONI 46 2 cm 18 2 71 5 cm 28 1 44 2 cm 17 4 22 0 cm 8 66 26 0 cm 10 2 47 5 cm 18 7 61 0 cm 24 0 MounƟng Pole Dual Angle MounƟng Pol LT812SAT LT812SUB ...

Page 5: ... Ø 35mm Con sistema di blocco a vite pin di sicurezza in acciaio e dispositivo di smorzamento ad aria per la massima velocità e facilità di regolazione Regolazione 1470 2180 mm CONNECTIONS CONNESSIONI INPUT ingresso Jack bilanciato INPUT Jack balanced sleeve ground tip hot ring cold INPUT ingresso XLR bilanciato maschio INPUT Balanced male XLR POWER OUTPUT uscite altoparlanti Connettore per cavo t...

Page 6: ...6 LT812SUB CONTROL PANEL FIG 1 LT812SUB PANNELLO DI CONTROLLO FIG 1 LT812SAT INPUT PANEL FIG 2 LT812SAT PANNELLO INGRESSO FIG 2 ...

Page 7: ...S FIG 3 CONFIGURAZIONI FIG 3 PROEL suggested equipment Mi and M series mixer use preferably balanced signal cables speakon power cable speakon power cable RIGHT LT812SAT LEFT LT812SAT LT812SUB LT812A sound system R L ...

Page 8: ...uipment capable of producing high sound pressure levels use hearing protectors while the equipment is in opera on Ear plugs or protectors in the ear canals or over the ears must be worn when opera ng the equipment in order to prevent permanent hearing loss if exposure is in excess of the limits set forth here Keep your s a en on that children and pets are more suscep ble to excessive noise levels ...

Page 9: ... avoid installa on on unstable elements such as furniture chairs and vibrant surfaces as stages or other speakers without appropriate fix point specifically designed to avoid speaker movement Then avoid the use of inadequate supports we suggest to use PROEL stands and accessories only In case of the speakers are provided of rigging points DO NOT SUSPEND THE SPEAKERS FROM THE HANDLES use exclusivel...

Page 10: ...a total loudspeaker protec on INSTRUCTIONS FIG 1 2 3 1 LEFT INPUT combo XLR JACK input This is a female combo connector which accepts a XLR or a JACK plug from almost any type of equipment with a balanced or unbalanced outputs The XLR input is wired as follows Pin 1 shield or ground Pin 2 posi ve or hot Pin 3 nega ve or cold The JACK input is wired as follows Tip posi ve or hot Ring nega ve or col...

Page 11: ...t and run it to the right LT812SAT speaker 11 POWER switch The apparatus is ON when the switch is in the I posi on use this switch to set the system power to ON or OFF NOTE When you shut down your equipment turn off the speaker first When powering up turn on the speaker last 12 LINE VOLTAGE selector This switch sets the AC voltage line of your country usually it is set by factory and isn t necessar...

Page 12: ...iodo di tempo Come suggerimento viene riportata la tabella dei tempi massimi di esposizione giornaliera al rumore al fine di evitare perdite di udito fonte della tabella è l ente per la salute degli Sta Uni OSHA Si fa presente inoltre che sia i bambini che gli animali domes ci sono più sensibili al rumore intenso IN CASO DI GUASTO In caso di guasto o manutenzione questo prodo o deve essere ispezio...

Page 13: ...chi e altri altoparlan non dota di fissaggi a a evitare spostamen dell altoparlante Quindi evitare di u lizzare suppor non adegua si consiglia di usare solo i suppor suggeri da PROEL Qualora gli altoparlan siano muni di pun di fissaggio per la sospensione NON SOSPENDERE GLI ALTOPARLANTI DALLE MANIGLIE usare esclusivamente ques pun di fissaggio Consultare a rezzis professionis o ingegneri stru ural...

Page 14: ...ONI FIG 1 2 3 1 LEFT INPUT ingresso COMBO XLR JACK Questo è un conne ore combinato XLR JACK femmina che preleva il segnale da pra camente qualsiasi apparecchio bilanciato o sbilanciato Le terminazioni dell ingresso XLR sono Pin 1 schermo o massa Pin 2 posi vo o caldo Pin 3 nega vo o freddo Le terminazioni dell ingresso JACK sono Tip punta posi vo o caldo Ring anello nega vo o freddo Sleeve manico ...

Page 15: ...posizione I Agite su questo tasto per accendere o spegnere il sistema NOTA Quando si spegne l impianto sonoro spegnere per primi gli altoparlan Quando si accende l impianto sonoro accendere gli altoparlan per ul mi 12 LINE VOLTAGE sele ore tensione di rete Questo sele ore imposta la tensione di rete della linea ele rica del vostro paese picamente è già impostato di fabbrica e non è necessario camb...

Page 16: ...REV 13 14 CODE 96MAN0092 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Reviews: