6.2
Malfunction
Analysis
on
Amplified
Part
Sequence
No.
Circuit
Function
Failure
1
Class
AB
Power
Output
‐
Power
supply
protection:
Any
of
the
short
circuits
of
power
output
transistor
(CH1/Q2,
Q3,
Q10,
Q11,
CH2/Q19,
Q20,
Q24,
Q25)
will
cause
the
high
current
and
power
supply
protection;
‐
Amplifier
protection:
+15
V/
‐
15V
is
derived
from
the
current
limiting
of
R31,
R40
and
D3,
D4,
if
the
power
supply
is
abnormal
it
will
lead
to
the
DC
output,
amplifier
will
go
into
protect
status;
‐
Clip
limit
doesn’t
work
–
check
whether
the
devices
of
D7,
D8,
D9,
D40,
LED1,
R22
is
damaged
or
not;
‐
Amplifier
self
‐
excitation
–
check
whether
the
device
of
C3,
C7,
C8,
C10,
C14
was
turn
bad.
‐
Crossover
distortion
:
check
whether
the
BE
voltage
of
the
negative
‐
positive
half
‐
wave
power
transistor
is
<0.2V
or
not,
then
check
the
value
of
temperature
compensation
transistor
Q
and
resistance
(R25,
R26,
R13)
is
changed;
‐
IC/5532
damaged,
unbalanced
of
the
of
positive
and
negative
bias
voltage,
has
DC
output
and
power
amplifier
goes
into
protection.
2
Overload/
Short
‐
circuit
Protection
‐
Output
short
‐
circuit
and
no
protection,
‐
Start–up
protection
3
Clip
Limit
Circuit
‐
No
clip
limit,
check
whether
the
D7
is
on;
‐
Clip
limit
delayed,
check
the
D9
and
R19;
‐
Wave
form
jitter
when
in
clip
limit;
‐
No
volume
gradually
increase
function
after
start
‐
up.
4
Over
‐
temperature
Protection
and
Delay
Circuit
‐
The
delay
circuit
protect
is
a
collection
of
VHF,
short
circuit,
over
‐
temperature,
DC
‐
protection,
as
well
as
start
‐
up
delay.
‐
When
the
Protection
function
and
start
‐
up
delay
is
abnormal
please
check
this
circuit.
5
DC
Protect
Circuit
‐
No
output
‐
relay
does
not
pull
‐
in,
first
check
whether
it
is
normal
for
24V
power
supply,
Q6
base
is
a
high
level.
‐
On
/
off
has
the
sound
of
shock
‐
a
long
pull
‐
in
on
the
relay;
Repairing
Guide:
1)
When
repairing
the
amplifier,
please
series
connect
a
100W—200W
lamp
to
start
the
equipment
in
order
to
avoid
the
damage
of
related
device;
2)
The
circuit
of
CH1
and
CH2
is
the
same
but
the
sequence
No.
of
device
is
different,
all
the
testing
parameter
can
be
shared;
3)
Power
amplifier
protection
means
the
power
supply
and
protection
indicator
on
the
panel
are
lit;
Summary of Contents for HP-X series
Page 1: ...1 Service Manual HPX Series Applicable Models HPX900 HPX1200 HPX2400 HPX2800...
Page 10: ...10 6 HPX900 Malfunction Analysis on Amplified Part 6 1 Circuit Diagram of Amplifier...
Page 16: ...16 10 HPX1200 Malfunction Analysis on Amplified Part 10 1 Circuit Diagram of Amplifier...
Page 18: ...18 11 HPX2400 2800 Malfunction Analysis on SMPS 11 1 Circuit Diagram of SMPS...
Page 20: ...20 12 HPX2400 2800 Malfunction Analysis on Amplified Part 12 1 Circuit Diagram of Amplifier...