PROEL DPX1000 User Manual Download Page 3

INDEX

TECHNICAL SPECIFICATIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . .3

SETUP AND RACK MOUNTING (FIG. 1)

 . . . . . . . . . . . . . . . . . . .4

LOUDSPEAKER CABLE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

CONNECTIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

FILTER RESPONSE (FIG.2)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

DIMENSIONS (FIG.3)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

FRONT PANEL (FIG.4)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

REAR PANEL (FIG.5)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

EXAMPLE A

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

EXAMPLE B

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

EXAMPLE C

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

EXAMPLE D

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

SAFETY AND PRECAUTIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . 10

IN CASE OF FAULT

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

TROUBLESHOOTING

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

CE CONFORMITY

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

PACKAGING, SHIPPING AND COMPLAINT

 . . . . . . . . . . . . . . . 11

WARRANTY AND PRODUCTS RETURN

 . . . . . . . . . . . . . . . . . . 11

INSTALLATION AND DISCLAIMER

 . . . . . . . . . . . . . . . . . . . . . . 11

POWER SUPPLY AND MAINTENANCE

 . . . . . . . . . . . . . . . . . . 11

GENERAL INFORMATION

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

INSTRUCTIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

INDICE

SPECIFICHE TECNICHE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

INSTALLAZIONE A RACK (FIG. 1)

 . . . . . . . . . . . . . . . . . . . . . . . . .4

CAVO ALTOPARLANTE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

CONNESSIONI

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

RISPOSTA FILTRI (FIG.2)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

DIMENSIONI (FIG.3)

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

PANNELLO FRONTALE (FIG.4)

 . . . . . . . . . . . . . . . . . . . . . . . . . . .6

PANNELLO POSTERIORE (FIG.5)

 . . . . . . . . . . . . . . . . . . . . . . . . .7

ESEMPIO A

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

ESEMPIO B

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

ESEMPIO C

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

ESEMPIO D

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

AVVERTENZE PER LA SICUREZZA

 . . . . . . . . . . . . . . . . . . . . . . 15

IN CASO DI GUASTO

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

PROBLEMATICHE COMUNI

 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

CONFORMITÀ CE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

IMBALLAGGIO, TRASPORTO E RECLAMI

 . . . . . . . . . . . . . . . . 16

GARANZIE E RESI

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

INSTALLAZIONE E LIMITAZIONI D’USO

 . . . . . . . . . . . . . . . . . . 16

ALIMENTAZIONE E MANUTENZIONE

 . . . . . . . . . . . . . . . . . . . 16

INFORMAZIONI GENERALI

 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

ISTRUZIONI

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

MODEL

DPX1000

DPX1500

DPX2000

MODELLO

DPX1000

DPX1500

DPX2000

Channels

2 (single) or 1 (bridge)

Canali

2 (singoli) o 1 (ponte)

Power 8 ohm *

350 W

500 W

650 W

Potenza Continua 8ohm*

350 W

500 W

650 W

Power 4 ohm **

500 W

750 W

1000 W

Potenza Continua 4ohm**

500 W

750 W

1000 W

Power BRIDGE 8 ohm **

1000 W

1500 W

2000 W

Pot. Cont. BRIDGE 8ohm**

1000 W

1500 W

2000 W

Output Stage

Class D

Stadio d'uscita

Classe D

Frequency response

20 Hz - 20 kHz

Risposta in Frequenza

20 Hz - 20 kHz

Input Sensitivity

+2.2 dBu (1.0 Vrms)

Sensibilità Ingresso

+2.2 dBu (1.0 Vrms)

Gain

34.5 dB

36 dB

37.2 dB

Guadagno

34.5 dB

36 dB

37.2 dB

Input Impedance

20 Kohm (bal) / 10 Kohm (unbal)

Impedenza Ingresso

20 Kohm (bilanciato) / 10 Kohm (sbilanciato)

Input Connectors

XLR-F (INPUT) XLR-M (LINK)

Connettori Ingresso

XLR-F (INPUT) XLR-M (LINK)

Output Connectors

NL4 Speakon

Connettori Uscita

NL4 Speakon

Controls

Level, HPF filter / BI-AMP / FLAT, Stereo / Parallel 

/ Bridge

Controlli

Level, HPF filter / BI-AMP / FLAT, Stereo / 

Parallel / Bridge

HPF/BI-AMP filter

LR 24dB / Oct. @ 100 Hz

Filtro HPF/BI-AMP

LR 24dB / Oct. @ 100 Hz

LED Indicators

PROT, LIMIT, SIGNAL meter, ON

Indicatori LED

PROT, LIMIT, SIGNAL meter, ON

Cooling

Variable speed DC fan

Raffreddamento

Ventole DC a velocità variabile

Protections

AC low power, DC voltage, Thermal, Short circuit, 

CLIP Limiter, VHF.

Protezioni

AC low power, DC voltage, Thermal, Short 

circuit, CLIP Limiter, VHF.

Damping Factor

> 60 @ 8 ohm

Fattore Smorzamento

> 60 @ 8 ohm

S/N Ratio

> 102 dB (unweighted)

Rapporto S/R

> 102 dB (non pesato)

THD+N

< 0.1 %

Disto Rumore

< 0.1 %

Power Supply

230 V~ or 120 V~ - 50/60 Hz

Tensione alim. di rete

230 V~ o 120 V~ - 50/60 Hz

Max Consumption

550 W

800 W

1050 W

Consumo massimo

550 W

800 W

1050 W

Rated Consumption***

185 W

265 W

350 W

Consumo nominale***

185 W

265 W

350 W

Weight

5 Kg 

 

(11 lb)

5.1 Kg 

 

(11.2 lb)

5.75 Kg 

 

(12.7 lb)

Peso

5 Kg 

 

(11 lb)

5.1 Kg 

 

(11.2 lb)

5.75 Kg 

 

(12.7 lb)

Dimensions (W x H x D)

483 x 89 x 382 mm (19 x 3.5 x 15 inch)

19 x 3.5 x 15 inch)

Dimensioni (LxAxP)

483 x 89 x 382 mm (19 x 3.5 x 15 inch)

* Continuous power under EIA Standard

** 40 ms tone burst, 

1KHz THD < 1%

*** Rated consumption is measured with pink noise with a crest factor of 12 

dB, this can be considered a standard music program.

* Potenza Continua Standard EIA

** 40 ms tone burst, 1KHz THD < 1%

*** Il consumo nominale �� misurato con un rumore rosa con un fattore di

** Il consumo nominale �� misurato con un rumore rosa con un fattore di 

cresta di 12 dB, considerato come un programma standard di musica.

TECHNICAL SPECIFICATIONS

SPECIFICHE TECNICHE

Summary of Contents for DPX1000

Page 1: ...DPX1000 DPX1500 DPX2000 2 channel power amplifier USER MANUAL MANUALE D USO...

Page 2: ...constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instr...

Page 3: ...7 2 dB Input Impedance 20 Kohm bal 10 Kohm unbal Impedenza Ingresso 20 Kohm bilanciato 10 Kohm sbilanciato Input Connectors XLR F INPUT XLR M LINK Connettori Ingresso XLR F INPUT XLR M LINK Output Con...

Page 4: ...LTOPARLANTE ENGLISH Loudspeaker Line Losses maximum permissible line lengths for 0 5dB losses voltage or spl ITALIANO Perdite di collegamento linee Altoparlanti massima lunghezza possibile per perdite...

Page 5: ...2 bridge negative 2 channel 2 positive canale 2 positivo 2 LINK rilancio ingresso XLR bilanciato femmina LINK Balanced female XLR ground hot cold n c INPUT ingresso Jack bilanciato INPUT Jack balanced...

Page 6: ...FRONT PANEL FIG 4 PANNELLO FRONTALE FIG 4 DIMENSIONS FIG 3 DIMENSIONI FIG 3 1 2 2 3 3 4 4 5 5 6 6 7 8 44 0 cm 17 3 8 81 cm 3 47 48 0 cm 19 0 28 8 cm 11 3 2 2 cm 0 87...

Page 7: ...REAR PANEL FIG 5 PANNELLO POSTERIORE FIG 5 9 10 14 11 9 10 12 13 15 16 17...

Page 8: ...et as PARALLEL for 2 channel pairs driven from 1 audio channels 1 1 R 1 1 8 minimum set as BRIDGE for doubled power for 1 loudspeakers driven from both audio channels and set as HPF if used in combina...

Page 9: ...h audio channels and set as BI AMP for 100Hz 24 dB oct low pass lter 1 2 IMPORTANT wire as speci ed above 1 1 mid high speaker 4 minimum subwoofer 4 minimum set as PARALLEL for 2 channel pairs driven...

Page 10: ...equipment capable of producing high sound pressure levels use hearing protectors while the equipment is in operation Ear plugs or protectors in the ear canals or over the ears must be worn when operat...

Page 11: ...or repaired Proel S p A is not responsible for any direct damage or indirect damage caused by product defectiveness INSTALLATION AND DISCLAIMER Proel products have been expressly designed for audio a...

Page 12: ...tenuates the level of the signal sent to the correspondent channel of the amplifier while in BRIDGE operation the channel control 1 operates as single control for the channel pair set as bridge The at...

Page 13: ...e following filter configurations HPF enables a 100Hz LR 24dB Oct High Pass Filter for both channels 1 and 2 this a useful feature for SAT TOP SPEAKERS or STAGE MONITORS see EXAMPLE B BI AMP enables a...

Page 14: ...e signal applied to channel 1 input if the amplifier is set in PARALLEL mode Always connect a loudspeaker with a minimum impedance of 4 ohm or more 15 Fan Fan Air cooling vent always keep it clear of...

Page 15: ...rto periodo di tempo Come suggerimento viene riportata la tabella dei tempi massimi di esposizione giornaliera al rumore al fine di evitare perdite di udito fonte della tabella l ente per la salute de...

Page 16: ...ati esclusivamente ad un utilizzo specifico di tipo sonoro segnali di ingresso di tipo audio 20Hz 20kHz Proel declina ogni responsabilit per danni a terzi causati da mancata manutenzione manomissioni...

Page 17: ...rotativo in modalit STEREO e PARALLEL attenua il livello del segnale inviato al canale corrispondente dell amplificatore mentre in modalit BRIDGE il controllo di livello 1 agisce singolarmente per la...

Page 18: ...ositivo e 1 per il negativo 12 HPF BI AMP FLAT Questo selettore permette la selezione di una delle seguenti configurazioni di filtraggio HPF abilita un filtro passa alto a 100Hz LR 24dB Oct per entram...

Page 19: ...del segnale applicato all ingresso del canale 1 se in modalit PARALLEL Collegare sempre un altoparlante con un impedenza minima di 4 ohm o superiore 15 Ventola Apertura per il flusso d aria della ven...

Page 20: ...REV 28 15 CODE 96MAN0117 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com...

Reviews: