background image

MANUALE UTENTE  -  INSTRUCTION MANUAL 

 
 
 
 
 
 
 
 

 
 
 

 

 

 

 
 
 
 
 
 
 

 

 
 

Base microfonica digitale per annunci  – Digital 

microphone console for announcement

 

 

BM8X8 

Summary of Contents for BM8X8

Page 1: ...MANUALE UTENTE INSTRUCTION MANUAL Base microfonica digitale per annunci Digital microphone console for announcement BM8X8 ...

Page 2: ...2 ...

Page 3: ...ONI D USO 4 2 DESCRIZIONE 6 3 PANNELLO FRONTALE 6 4 PANNELLO POSTERIORE 7 5 INSTALLAZIONE ED ALIMENTAZIONE 8 6 UTILIZZO DELLA POSTAZIONE 9 7 COLLEGAMENTO DELLE UNITA DI ESPANSIONE EXBM08X8 9 8 CARATTERISTICHE TECNICHE 10 ...

Page 4: ...one non interferisca con l adeguata ventilazione Per esempio l apparecchio non deve essere collocato su un letto copri divano o superfici simili che possono bloccare le aperture di ventilazione o posto in una installazione ad incasso come una libreria o un armadietto che possono impedire il flusso d aria attraverso le aperture di ventilazione Calore L apparecchio deve essere posto lontano da fonti...

Page 5: ...hio al di là di quanto descritto nelle istruzioni di funzionamento Ogni altra riparazione deve essere affidata a personale specializzato IMPORTANTI NORME DI SICUREZZA Installare seguendo le istruzioni Il voltaggio d alimentazione dell unità è abbastanza elevato per evitare il rischio di scosse elettriche non installare collegare o sconnettere l alimentazione quando l apparato è acceso Non aprire m...

Page 6: ...densatore elettrete contraddistinto da un elevata sensibilità e da un ampia risposta in frequenza 8 tasti di selezione a zone o gruppi di zone tasto ALL e tasto TALK La console dispone inoltre di 2 tipologie di DIN DON deselezionabili a due note e a quattro note utilizzabili per richiamare l attenzione prima degli annunci ed è corredata di alimentatore locale 230 115V 24V DC La comunicazione tra l...

Page 7: ...ata da un altra base led di zona illuminato di rosso premendo ALL CALL l indicatore rimane spento e non sarà possibile effettuare nessuna chiamata 7 Indicatore ALL CALL Il LED è acceso luce blu quando il pulsante ALL CALL è inserito e si spegne quando il pulsante ALL CALL viene disinserito 8 Label estraibile promemoria zone Le etichette possono essere applicate dall utente per individuare le sorge...

Page 8: ... quattro toni OFF Il tono di preavviso è disabilitato 5 INSTALLAZIONE ED ALIMENTAZIONE Attenzione Non posizionare il dispositivo in posti soggetti a elevate vibrazioni o particolarmente esposti all umidità e alla polvere Per l installazione e connessione contattare solo un installatore autorizzato al fine di evitare danni alle apparecchiature Le basi dispongono di 4 piedini in gomma che ne impedis...

Page 9: ...te microfono Per terminare la chiamata rilasciare il tasto TALK Nota Alla pressione del tasto di selezione della singola zona o di generale se risulteranno zone occupate non sarà possibile effettuare la chiamata in nessuna zona libera o occupata Se una zona o più zone sono occupate dalla diffusione di un messaggio di allarme su di esse non sarà possibile effettuare una chiamata sarà però possibile...

Page 10: ...68 CEE secondo i seguenti standard EN 50082 1 1997 EN 55013 1990 EN 55020 1994 inoltre è conforme alla Direttiva 73 23 CEE Bassa Tensione e successive modifiche 93 68 CEE secondo il seguente standard EN 60065 1998 MODELLO BM8X8 Tipo microfono cardioide Sensibilità 4mV Pa Lunghezza gooseneck 300 mm Livello uscita Audio digitale Controllo Toni Livello Trimmer su pannello posteriore Rapporto S N 100 ...

Page 11: ...1 INDICE 1 IMPORTANT SAFETY INSTRUCTIONS 12 2 DESCRIPTION 14 3 FRONT PANEL 14 4 BACK PANEL 15 5 INSTALLATION AND POWER SUPPLY 16 6 USE 16 7 EXBM08X8 Expansion units connection 17 8 TECHNICAL FEATURES 18 ...

Page 12: ...RUCTIONS Water and moisture This apparatus should not be used near water i e bathtub kitchen sink swimming pools etc Ventilation This apparatus should be placed in a position that doesn t interfere with its correct ventilation This unit for example should not be placed on a bed sofa cover o similar surfaces that could cover ventilation openings or placed in a built in installation such a bookcase ...

Page 13: ...arked change in performance If the product has been dropped or has been damaged in any way Maintenance The user shouldn t attempt maintenance not described in this user s manual All maintenance should be performed by qualified personnel only IMPORTANT SAFETY INSTRUCTIONS Install this unit following owner s manual instructions Do not install connect or disconnect power supply when the unit is power...

Page 14: ...lusively used with the digital MATRIX88 BM8X8 features a high sensitivity electret condenser microphone with a wide frequency response 8 zone selection buttons an ALL button and a TALK button BM8X8 also features a switchable 2 note 4 note chime and is provided with a local 230 115V 24V DC power supply Matrix and console communicate through a CAT5UTP cable This product is CE compliant 3 FRONT PANEL...

Page 15: ...ed the indicator will remain off and no call will be made 7 ALL CALL Indicator This blue LED is on when the ALL CALL button is pushed in and it will turn itself off when the ALL CALL button is disengaged 8 Custom Zone Label Labels identifying sound sources can be printed out directly by the user 9 Zone Indicators Two color LED it identifies the zone status RED the zone is busy with another paging ...

Page 16: ...usty environment For installation and connection contact only authorized technicians in order to avoid any damage to the device The bottom of the device features four rubber feet to prevent slipping alternatively the device can be semi recessed in its supporting surface After having supplied power to the console through the cable provided connect BM8X8 to MATRIX88 with a standard CAT5UTP cable MAT...

Page 17: ...n alarm message is being played or if any zone is already busy when the ALL CALL or a zone button is selected no announcement can be made on any zone either busy or free If a zone or several zones are playing an alarm message no calls can be made on those zones but it will be possible to make calls on the free channels 7 EXBM08X8 Expansion units connection If more speaker zones are needed the syst...

Page 18: ...rimmer on back panel S N Ratio 100 dB Frequency Response 3dB 150Hz 8KHz Power Supply 12 V DC phantom or local Dimensions LxDxH 232 x 131 x 61 mm Weight 0 95 Kg This product complies with Directive 89 336 EEC Electromagnetic Compatibility and later changes 92 31 EEC and 93 68 EEC according to the following standards EN 50082 1 1997 EN 55013 1990 EN 55020 1994 furthermore it complies with Directive ...

Page 19: ...19 ...

Page 20: ...20 PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 81241 Fax 39 0861 887862 E mail info proelgroup com www proel com ...