25
10.5.
Program A4
–
parameters of individual premises
This subprogram enables to change parameters of a given premises (a logical number is used). The
available parameters are listed in Table 1.
Option
Description
Symbol
office mode
automatic opening the lock when handset is raised
lock code lock
blockade on the use of lock code for this property
mute confirmation of the lock
code
mute confirmation of the use of lock code in the
device.
feedback blockade
blockade of the use of feedback from the premises
lock opening blockade with
button
door opening blockade by pressing a button in the
device
alternative lock code event
property generates code(2) code(3) events
alternative RFID event
assigned IDs generate an RFID event(1)
forcing impulse addressing
this property will be addressed using the old
method (for pc255) despite the new type of
addressing
individual ringtone type
individually set ringtone type 0-5
individual ringtone volume
individually set ringtone volume 0-7
Table 1. Options available for individual premises
After entering subprogram, the cassette will receive one by one the summed up line flags
(message
), ringtone (
) and ringtone volume (
). Messages are displayed
alternately with entered values. If the parameter is not entered, only a message is displayed. Going
to the next field is possible after pressing a button
(it is connected with saving the currently
displayed field). In order to clear a given parameter, press the button during display and accept
it with button
.
Parameters with FLA_ symbol are set as flags. In order to set the appropriate configuration of
these parameters, it is necessary to sum up their weights, which are given in Table 2.