PROEL ACEX2 Owner'S Manual Download Page 2

 

 

1.  IMPORTANT SAFETY INSTRUCTIONS 

 

       

 

 

CAUTION:   

To reduce the risk of electric shock do not remove cover (or back panel). No 
user serviceable parts inside. Refer servicing to qualified personnel only. 

 

WARNING:

 

To reduce the risk of fire or electric shock, do not expose this apparatus to 
rain or moisture. 

 
                           

This  symbol is intended to alert the user of the presence of uninsulated 
dangerous voltage within the product enclosure that may be of sufficient 
magnitude to constitute a risk of electric shock to persons. 

 
 
          

This  symbol  is  intended  to  alert  the  user  of  the  presence    of  important 
operating and maintenance (servicing) instruction in the literature 
accompanying the appliance. Please carefully read the owner’s manual. 

 

 

INSTRUCTIONS: 
 

All safety and operating instructions should be read before the product is operated. 
 

Retain these instructions: 

All safety and operating instructions should be retained for future reference.  
This owner’s manual should be considered as a part of the product and it must accompany it 
every time, and delivered to the new user when this product is sold. In this way the new owner will 
be aware of all the installations, operating and safety instructions.  

 
Heed all warnings: 

All warnings on the product and in owner’s manual should be adhered to

.  

Heed all warnings.

 

 
Follow all instructions: 

All operating and user’s instructions must be followed. 

 
 
 

 
 
 
 
 

Summary of Contents for ACEX2

Page 1: ...OWNER S MANUAL STEREO COMPRESSOR ACEX2 ...

Page 2: ...ating and maintenance servicing instruction in the literature accompanying the appliance Please carefully read the owner s manual INSTRUCTIONS All safety and operating instructions should be read before the product is operated Retain these instructions All safety and operating instructions should be retained for future reference This owner s manual should be considered as a part of the product and...

Page 3: ...ower source type specified in this owner s manual or on the unit If the supplied AC power cable plug is different from wall socket please contact an electrician to change the AC power plug Grounding or Polarization All precautions must be observed in order to avoid grounding or polarization defeating Unit metal parts are grounded through the AC power cord If the AC power outlet doesn t have ground...

Page 4: ... in fire or electric shock Damages requiring services Don t attempt to do operations not described in this user s manual In the following cases please refer to an authorized maintenance center or skilled personnel When the unit works improperly or it doesn t work at all If power cord or plug are damaged If liquid has spilled or objects have fallen into the unit The unit has been exposed to rain Th...

Page 5: ...for any damage that occurs due to a wrong unit installation Thank you for choosing one of Proel products and for your confidence towards our brand synonymous of professionalism accuracy high quality and reliability All our products are CE approved and designed for continuous use in professional installation systems Description This unit has been designed to manage the dynamics of two audio signal ...

Page 6: ...l 7 Compressor section RELEASE time manual control 8 Selection switch to choose AUTO or manual attack release time 9 Compressor section OUTPUT level control 10 CH1 CH2 GAIN REDUCTION meters 11 Enhancer section PROCESS control Rear panel description fig 2 1 AC IEC socket and fuse holder 2 AC voltage selector 3 DC power supply terminals 4 XLR 6 3mm 1 4 TRS jack INPUT connectors 5 XLR 6 3mm 1 4 TRS j...

Page 7: ...This unit has two independent input output channels CH1 and CH2 Each channel is supplied with a balanced XLR and a balanced 6 3mm 1 4 TRS jack The TRS jacks can be used in an unbalanced way by just connecting tip and sleeve TS connection only ...

Page 8: ...he unit press the POWER switch ON b To turn off the unit press the POWER switch OFF c Gate expander section setting The THRESHOLD fig 1 ref 1 control adjusts the level within OFF 10dB range Signals under the set value will be cut allowing noise and unwanted signals reduction unless when the THRESHOLD is set OFF To better understand the way this section works please do some tests with noisy signals...

Page 9: ...trol can be used to set the level in the most suitable way for your application and or recover gain loss due to compressor activity You can visually control the compressor gain reduction for each channel by GAIN REDUCTION meters fig 1 ref 10 e Enhancer section setting This section has just the PROCESS fig 1 ref 11 control with range from OFF to 6 This control is useful to recover signal brightness...

Page 10: ... 6 3 mm 1 4 TRS jack Output impedance 40 Ohm balanced Max output level 21dBu balanced and unbalanced Frequency response 20Hz 20KHz 0db 1dB T H D N 0 05 1kHz 4dB I M D SMPTE 0 01 10dBu Signal to noise ratio 93dB unity gain Signal to noise ratio 97dB all sections off Crosstalk 85dB 20kHz AC power supply 115 V 230 V 60Hz 50Hz DC power supply 24V Dimensions WxHxD 483mm x 44mm x 217mm 19 x 8 54 x 1 75 ...

Page 11: ...50082 1 1997 EN 55013 1990 EN 55020 1994 This unit complies with CE Directive 73 23 CEE Low Voltage and following modifications 93 68 CEE by European Specifications EN 60065 1998 Disclaimer Proel SpA pursue a policy of continuous research and development Proel SpA reserve the right to modify product circuitry and appearance at any moment without prior notice ...

Page 12: ...PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 81241 Fax 39 0861 887862 E mail info proelgroup com installation proelgroup com ...