background image

2

Watch for these symbols:
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence 

of uninsulated “dangerous voltage” within the product’s enclosure, that may be of sufficient magnitude to constitute 

a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in the literature accompanying the appliance.

IMPORTANT SAFETY INSTRUCTIONS

1.   Read these instructions.

2.   Keep these instructions.

3.   Heed all warnings.

4.   Follow all instructions.

5.   Do not use this apparatus near water.

6.   Clean only with dry cloth.

7.   Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.   Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat.

9.   Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with 

one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade 

or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an 

electrician for replacement of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the 

point where they exit from the apparatus.

11.  Only use attachments/accessories specified by the manufacturer.

12.  Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. 

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.  Unplug this apparatus during lightning storms or when unused for long periods of time.

14.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged 

in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the 

apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15.  Warning: to reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

16.  Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as 

vases, are placed on the equipment.

17.  To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac 

receptacle.

18.  The mains plug of the power supply cord shall remain readily operable.

19.  This apparatus contains potentially lethal voltages. To prevent electric shock or hazard, do not remove the  

chassis, input module or ac input covers. No user serviceable parts inside. Refer servicing to qualified service 

personnel.

20.  The loudspeakers covered by this manual are not intended for high moisture outdoor environments. Moisture 

can damage the speaker cone and surround and cause corrosion of electrical contacts and metal parts. Avoid 

exposing the speakers to direct moisture.

21.  Keep loudspeakers out of extended or intense direct sunlight. The driver suspension will prematurely dry out and 

finished surfaces may be degraded by long-term exposure to intense ultra-violet (UV) light.

22.  The loudspeakers can generate considerable energy. When placed on a slippery surface such as polished wood 

or linoleum, the speaker may move due to its acoustical energy output.

23.  Precautions should be taken to assure that the speaker does not fall off a stage or table on which it is placed.

24.  The loudspeakers are easily capable of generating sound pressure levels (SPL) sufficient to cause permanent 

hearing damage to performers, production crew and audience members. Caution should be taken to avoid 

prolonged exposure to SPL in excess of 90 dB.

25.  Check periodically that the slots for its proper ventilation and heating dissipation are not obstructed by dust, 

remove the dust using a dry brush or a compressed air gun.

26.  Before connecting the product to the mains outlet make certain that the mains line voltage matches that shown 

on the rear of the product, a tolerance of up to ±10% is acceptable.

27.  Inside the amplified loudspeakers are present special safety devices such as: 

 

ü

 Transformer and amplifier over-heating protection. 

 

ü

 Protection against excessive power applied at each speaker.

28.  THE REPLACEMENT OF FUSES INSIDE THE APPARATUS MUST BE MADE ONLY BY QUALIFIED PERSONNEL.

CAUTION

To prevent electric shock hazard,
do not connect to main power
supply while grille is removed.

Summary of Contents for 8032496472636

Page 1: ...WX8A WX10A active wedge monitors USER MANUAL MANUALE D USO ...

Page 2: ...e risk of fire or electric shock do not expose this apparatus to rain or moisture 16 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases are placed on the equipment 17 To completely disconnect this apparatus from the ac mains disconnect the power supply cord plug from the ac receptacle 18 The mains plug of the power supply cord shall r...

Page 3: ...erly used and warranty is still valid then the unit will be replaced or repaired Proel S p A is not responsible for any direct damage or indirect damage caused by product defectiveness Proel S p A declines any liability for damages to objects or persons caused by lacks of maintenance improper use modifications installation not performed with safety precautions and at the state of the art The infor...

Page 4: ...FCC STATEMENT This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s a...

Page 5: ...ong polyurethane painting making them resistant to any abuse The custom designed coaxial transducers are able to provide a perfect HF and LF alignment and a controlled directivity for a perfect listening from any position The WX monitors are available in two models offering the perfect solution for different monitoring situations The ultra compact WX8A is able to offer a high performance monitorin...

Page 6: ...t signal level 6 PRESET MONITOR FOH selector This switch allows the selection between two equalisation settings suited to two different uses MONITOR suited for stage monitoring sound reinforcement for an improved feedback rejection FOH this preset has been designed for typical sound reinforcement applications with the speaker mounted on floor stand 7 POWER switch Speaker is ON when the switch is i...

Page 7: ...ch polyurethane paint Pole Adapter 1 x side 1 x side Handles 1 x sides 1 x sides Monitor taper 36 36 Weight 8 kg 17 6 lb 10 kg 22 0 lb Dimensions W x H x D 325 x 336 x 233 mm 390 x 396 x 270 mm Rated consumption is measured with pink noise with a crest factor of 12 dB this can be considered a standard music program TECHNICAL SPECIFICATIONS ACCESSORIES FRE300BK Professional aluminium floor stand fo...

Page 8: ...cavo di alimentazione o la spina danneggiati del liquido è stato versato o sono caduti oggetti nell apparecchio l apparecchio è stato esposto a pioggia o umidità non funziona normalmente o è stato fatto cadere 15 Avvertenza per ridurre il rischio di incendi o scosse elettriche non esporre questo apparecchio a pioggia o umidità 16 Non esporre questa apparecchiatura a gocciolamenti o spruzzi e assic...

Page 9: ...eriali Gli utenti domestici sono invitati a contattare il rivenditore presso il quale è stato acquistato il prodotto o l ufficio locale preposto per tutte le informazioni relative alla raccolta differenziata e al riciclaggio per questo tipo di prodotto Gli utenti aziendali sono invitati a contattare il proprio fornitore e verificare i termini e le condizioni del contratto di acquisto Questo prodot...

Page 10: ...P rosso dell amplificatore Livello differente sui canali Controllare se si stanno usando cavi bilanciati su un canale e sbilanciati sull altro ciò può comportare una notevole differenza di livello sui canali Assicurarsi che entrambi i controlli di livello LINE IN di ciascun altoparlante siano nella stessa posizione Rumore Ronzio Abilitare l interruttore GND LIFT sul pannello posteriore se il probl...

Page 11: ...a in poliuretano che li rende resistenti a qualsiasi eccesso I trasduttori coassiali custom sono in grado di fornire un perfetto allineamento tra HF e LF e una direttività controllata per un ascolto perfetto da qualsiasi posizione I monitor WX sono disponibili in due modelli offrendo la soluzione ideale per diverse situazione di monitoraggio Il WX8A ultra compatto è in grado di offrire un sistema ...

Page 12: ...ESET MONITOR FOH Permette la selezione fra due differenti impostazioni di equalizzazione adattate a due differenti usi MONITOR adatto per l uso del sistema come monitor di palco ottimizzato per ridurre fenomeni di feedback FOH adatto al tipico uso per il rinforzo del suono con l altoparlante montato su supporto da pavimento 7 POWER interruttore di accensione L altoparlante è acceso ON quando è nel...

Page 13: ...lex Altoparlante bassi 8 woofer bobina da 2 10 woofer bobina da 2 5 VC Altoparlante alti Driver a compressione da 1 1 VC Driver a compressione da 1 1 35 VC Copertura angolare 60 60 Risposta in Frequenza 80 Hz 20 kHz 70 Hz 20 kHz SPL massima a 1m picco 122 dB 123 dB Potenza Continua Amplificatore 250 W Classe D con SMPS 250 W Classe D con SMPS Impedenza ingresso 30 kohm sbilanciato 15 kohm bilancia...

Page 14: ...PROEL NL4FX PROEL code NL4FX Codice PROEL NL4FX SPEAKER POWER OUTPUTS Neutrik NL4 Speakon Cable Connector ground hot cold INPUT ingresso Jack sbilanciato INPUT Jack unbalanced ground tip hot cold nota connettere insieme cold e ground per cavi da bilanciato a sbilanciato note connect both cold and ground to make cable from balanced to unbalanced 2 1 2 1 20mm 0 8 8mm 0 3 RED BLACK positive red rosso...

Page 15: ...15 CONNECTION EXAMPLE FIG 3 ESEMPIO COLLEGAMENTO FIG 3 DIMENSIONS DIMENSIONI 23 3 cm 9 17 33 6 cm 13 2 32 5 cm 12 8 WX8A WX10A 27 0 cm 10 6 39 6 cm 15 6 39 0 cm 15 4 From mixer single doubled ...

Page 16: ...REV 51 19 CODE 96MAN0155 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Reviews: