Version : V1.3 sep-15
Page
4
of
4
9.
Heat the extruder (+/-60˚C).
Once it’s hot enough, make sure to hold the heaterblock with
some pliers and screw the nozzle back on to the hotend. Make
sure the brass nut is thight to the heaterblock.
Carefull!!! The hotend is warm. Do not touch it!
The distance between nozzle and heaterblock should be
1.5mm!
10.
Mount the extruder back with 4 bolts.
MAKE SURE The extruder is exactly aligned above
the hotend!!!
11.
If you’ve done all steps recalibrate your printer before you
start with printing. Follow the calibration on the User manual
(Chapter 11.1 Nozzle ali 11.2 Calibration 2
nd
extruder)
You’ve successfully complete this procedure.