1.
Verify the unit is not connected to a power source.
2.
(Optional) To install the backup module, carefully align the P1 connector on the interface
module with the J1 connector on the backup module.
Using only fingertip pressure
to
ensure that neither circuit board bends or flexes, firmly seat the connectors. Secure the
backup module to the interface module using the supplied screws and standoff posts.
3.
Slide the interface module into the option slot until the module is firmly positioned
against the chassis.
4.
Secure the screws at both edges of the module.
G
ROUND
THE
R
OUTER
1.
Strip one end of the ground wire to the length required for the ring terminal. (Ground wire
and ring terminal are supplied by the user. For more detailed grounding specifications,
please refer to the
ProCurve Secure Router Installation Guide
.)
2.
Crimp the ground wire to the ring terminal, using a crimp tool of the appropriate size.
3.
Attach the ring terminal to the chassis as shown in the figure to the right.
4.
Connect the other end of the ground wire to a suitable grounding point at your site.
5.
Apply power to the unit.
Note
For information on installing the Encryption and Compact Flash modules
please refer to the ProCurve Secure Router Installation Guide included in
your router shipment.
C
ONNECT
TO
THE
P
RO
C
URVE
S
ECURE
R
OUTER
7102dl C
ONSOLE
Before connecting to the ProCurve Secure Router 7102dl
Console
interface you will need the
following items: VT100 terminal or PC (with VT100 terminal emulation software) and the serial
cable (5184-1894) supplied with your router. (This is the same console cable used in other
ProCurve switches such as the 5300xl series.)
1.
Connect the DB-9 (female) connector of your cable to the DB-9 DTE (male)
Console
interface on the front panel of the unit.
2.
Connect the loose end of the cable to the VT100 terminal or PC (with terminal emulation
software).
3.
Open a VT100 terminal session to the ProCurve Secure Router 7102dl using the
following settings: 9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press
<Enter>
to
activate the HP Command Line Interface.
4.
Enter
enable
at the
>
prompt.
5.
Enter the password when prompted or press
<Enter>
if you have not yet set a password.
Console
Power
Fault
Eth 0/1
Eth 0/2
Stat
Stat
Slots
1
2
Bkp
Bkp
Tx
Tx
Rx
Rx
dl
dl
ProCurve 7102dl
Secure Router
J8752A