ProCurve J8752A Quick Start Manual Download Page 1

61195880L1-13B, April 2005

www.procurve.com

Copyright 2005 Hewlett-Packard Development Company, LP

Quick Start Guide

5991-2112

ProCurve Secure Router 7102dl

J8752A

I

NSTALL

 

THE

 I

NTERFACE

 M

ODULE

1.

Verify the unit is not connected to a power source.

2.

(Optional) To install the backup module, carefully align the P1 connector on the interface 
module with the J1 connector on the backup module. 

Using only fingertip pressure

 to 

ensure that neither circuit board bends or flexes, firmly seat the connectors. Secure the 
backup module to the interface module using the supplied screws and standoff posts. 

3.

Slide the interface module into the option slot until the module is firmly positioned 
against the chassis.

4.

Secure the screws at both edges of the module.

G

ROUND

 

THE

 R

OUTER

1.

Strip one end of the ground wire to the length required for the ring terminal. (Ground wire 
and ring terminal are supplied by the user. For more detailed grounding specifications, 
please refer to the 

ProCurve Secure Router Installation Guide

.)

2.

Crimp the ground wire to the ring terminal, using a crimp tool of the appropriate size.

3.

Attach the ring terminal to the chassis as shown in the figure to the right.

4.

Connect the other end of the ground wire to a suitable grounding point at your site.

5.

Apply power to the unit.

Note

For information on installing the Encryption and Compact Flash modules 
please refer to the ProCurve Secure Router Installation Guide included in 
your router shipment.

C

ONNECT

 

TO

 

THE

 P

RO

C

URVE

 S

ECURE

 R

OUTER

 7102dl C

ONSOLE

Before connecting to the ProCurve Secure Router 7102dl 

Console

 interface you will need the 

following items: VT100 terminal or PC (with VT100 terminal emulation software) and the serial 
cable (5184-1894) supplied with your router. (This is the same console cable used in other 
ProCurve switches such as the 5300xl series.)

1.

Connect the DB-9 (female) connector of your cable to the DB-9 DTE (male) 

Console

 

interface on the front panel of the unit.

2.

Connect the loose end of the cable to the VT100 terminal or PC (with terminal emulation 
software).

3.

Open a VT100 terminal session to the ProCurve Secure Router 7102dl using the 
following settings: 9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press 

<Enter>

 to 

activate the HP Command Line Interface.

4.

Enter 

enable

 at the 

>

 prompt.

5.

Enter the password when prompted or press 

<Enter>

 if you have not yet set a password.

Console

Power

Fault

Eth 0/1

Eth 0/2

Stat

Stat

Slots

1

2

Bkp

Bkp

Tx

Tx

Rx

Rx

dl

dl

ProCurve 7102dl
Secure Router
J8752A

Reviews: