61195880L1-13C, August 2005
Printed in the USA
Copyright 2005 Hewlett-Packard Development Company, LP
Quick Start Guide
5991-2112
ProCurve Secure Router 7102dl
J8752A
E
NABLE
T
ELNET
A
CCESS
The following steps create an IP address (2.2.2.1 /24) for Ethernet port 0/1, an enable password
of
enablepw
, and a password of
secretpw
for Telnet access.
1.
At the
(config)#
prompt, enter
interface eth 0/1
to access the configuration parameters for
the Ethernet port located on the base unit.
2.
Enter
ip address 2.2.2.1 /24
to assign an IP address to the Ethernet port using a 24-bit
subnet mask.
3.
Enter
no shutdown
to activate the interface to pass data.
4.
Enter
exit
to exit the Ethernet interface commands and return to the Global Configuration
mode.
5.
Verify that the prompt of your unit displays
(config)#
.
6.
Enter
line telnet 0 4
to change the configuration parameters for the Telnet session.
7.
Enter
login
to initiate Telnet access.
8.
Enter
password secretpw
to change the login password for the Telnet session.
9.
Enter
exit
to return to the Global Configuration mode.
10. Verify that the prompt of your unit displays
(config)#
.
11. Enter
enable password enablepw
to set the Enable Security mode password.
12. Enter
exit
to return to the Enable mode.
13. Enter
write memory
to save the current configuration to memory.
E
NABLE
W
EB
GUI A
CCESS
To enable Web GUI access, an IP address for an Ethernet port must be assigned. Refer to
Enable Telnet Access
above. Enable HTTP and HTTPS access and configure a username and
password. The example below creates a username of
manager
and a password of
webpw
.
Once configured, use a Web browser to access the IP address.
1.
Verify that the prompt of your unit displays
(config)#
.
2.
Enter
ip http sever
to enable HTTP connection. Enter
ip http secure-server
to enable
SSL server connection.
3.
Enter
username manager password webpw
to set the password.
4.
Enter
exit
to return to the Enable mode.
5.
Enter
write memory
to save the current configuration to memory.
6.
Open your web browser, and enter the unit’s IP address into the browser address line (e.g.,
http://2.2.2.1).
Note
For safety information for the routers and all modules, please refer to the
safety and ESD precautions in the
ProCurve Secure Router Installation
Guide
included in your router shipment.
C
OMMANDS
Refer to the
SROS Command Line Interface Reference Guide
(provided on the SROS ProCurve
Documentation CD) for details on configuring the system using the command line interface.
C
ONSOLE
P
INOUT
Pin
Name
Description
1
—
Unused
2
RD
Receive Data (input)
3
TD
Transmit Data (output)
4
DTR
Data Terminal Ready (output)
5
SG
Signal Ground
6
DSR
Data Set Ready (input)
7
RTS
Request to Send (output)
8
CTS
Clear to Send (input)
9
—
Unused
E
THERNET
P
INOUT
Pin
Name
Description
1
TX1
Transmit Positive
2
TX2
Transmit Negative
3
RX1
Receive Positive
4, 5
—
Unused
6
RX2
Receive Negative
7, 8
—
Unused