The following steps create an IP address (2.2.2.1 /24) for Ethernet port 0/1, an enable password 
of 

enablepw

, and a password of 

secretpw

 for Telnet access.

1.

At the 

(config)#

 prompt, enter 

interface eth 0/1

 to access the configuration parameters for 

the Ethernet port located on the base unit.

2.

Enter 

ip address 2.2.2.1 /24 

to assign an IP address to the Ethernet port using a 24-bit 

subnet mask.

3.

Enter 

no shutdown

 to activate the interface to pass data.

4.

Enter 

exit

 to exit the Ethernet interface commands and return to the Global Configuration 

mode.

5.

Verify that the prompt of your unit displays 

(config)#

.

6.

Enter 

line telnet 0 4

 to change the configuration parameters for the Telnet session.

7.

Enter 

login

 to initiate Telnet access.

8.

Enter 

password secretpw

 to change the login password for the Telnet session.

9.

Enter 

exit

 to return to the Global Configuration mode.

10. Verify that the prompt of your unit displays 

(config)#

.

11. Enter 

enable password enablepw

 to set the Enable Security mode password.

12. Enter 

exit

 to return to the Enable mode.

13. Enter 

write memory

 to save the current configuration to memory.

E

NABLE

 W

EB

 GUI A

CCESS

To enable Web GUI access, an IP address for an Ethernet port must be assigned. Refer to 

Enable Telnet Access

 above. Enable HTTP and HTTPS access and configure a username and 

password. The example below creates a username of 

manager

 and a password of 

webpw

Once configured, use a Web browser to access the IP address.
1.

Verify that the prompt of your unit displays 

(config)#

.

2.

Enter 

ip http sever

 to enable HTTP connection. Enter 

ip http secure-server

 to enable 

SSL server connection.

3.

Enter 

username manager password webpw

 to set the password.

4.

Enter 

exit

 to return to the Enable mode.

5.

Enter 

write memory

 to save the current configuration to memory.

6.

Open your web browser, and enter the unit’s IP address into the browser address line (e.g., 
http://2.2.2.1).

Note

For safety information for the routers and all modules, please refer to the 
safety and ESD precautions in the 

ProCurve Secure Router Installation 

Guide

 included in your router shipment.

C

OMMANDS

Refer to the 

SROS Command Line Interface Reference Guide 

(provided on the SROS ProCurve 

Documentation CD) for details on configuring the system using the command line interface.

C

ONSOLE

 P

INOUT

Pin

Name

Description

1

Unused

2

RD

Receive Data (input)

3

TD

Transmit Data (output)

4

DTR

Data Terminal Ready (output)

5

SG

Signal Ground

6

DSR

Data Set Ready (input)

7

RTS

Request to Send (output)

8

CTS

Clear to Send (input)

9

Unused

E

THERNET

 P

INOUT

Pin

Name

Description

1

TX1

Transmit Positive

2

TX2

Transmit Negative

3

RX1

Receive Positive

4, 5

Unused

6

RX2

Receive Negative

7, 8

Unused

Reviews: