13/16
2014/05 - Indice de révision : D - code : 0034401
CONNECTION•OF•THE•CLEANING•MANIFOLD BOOSTER•PUMP (Option)
The booster pump is powered via a cable 3 x 2.5
2
connected to terminals 2 and 6 of the contactor
located to the left of the 220 V power supply. Connect the earth wire of this cable to the earth
terminal.
Note: The cleaning manifold is not compatible with pools more than 6 metres wide.
The cleaning manifold will clean the cover each time it is opened or closed if its control switch (to the
right of the on/off switch) is closed.
WIRING DIAGRAM
Electrical box connection terminals
Power supply 220 V + Earth
Ferrite ring
Key switch box
AQUAMAT 3001
Connection box
Booster
(cleaning manifold option)
To the AQUAMAT motor
(already cabled)