CAUTION 
 

1.

 

DO NOT use the unit for powering devices that require higher current than the maximum - otherwise 
damage may occur to the unit. 

2.

 

DO NOT replace the fuse and operate the unit before rectifying the problem that caused it to fail. Always 
replace the fuse with the same rated type. Always unplug the unit before attempting to replace the fuse. 

3.

 

If the external power cable or cord of this unit is damaged, it must be replaced by the same or equivalent 
unit from the manufacturer or service agent. The supply cord and plug must be installed and protected in 
accordance with national wiring rules. 

 
 
SAFETY PRECAUTIONS 
 

1.

 

NEVER remove the metal cover of the power supply with the AC power connected. Allow the unit to cool 
before opening the cover. Some components may burn your hand in the event of a component failure. Only 
qualified personal should open the cover. 

2.

 

NEVER touch the unit with wet hands or allow it to become wet. 

3.

 

NEVER operate the unit if foreign materials such as metallic objects, liquids or other debris have fallen inside. 
Return to the manufacturer or dealer for checking and repair. 

4.

 

NEVER operate the unit if it has been damaged. The voltage regulation circuitry may have been disabled, 
resulting in high voltage and damage to your equipment. 

5.

 

NEVER allow foreign objects to come into connect with the DC output terminals. 

6.

 

NEVER block the vents - including the cooling fan outlet. 

7.

 

ONLY connect to the AC mains outlet when in use, at all other times disconnect the power supply from the AC 
mains outlet. 

 
 
CONNECTION AND OPERATION 
 

1.

 

Make sure the input AC power source is as per the label before plugging in the unit. 

2.

 

Turn ON the power supply and adjust the output voltage to match that of your equipment. Adjust the 
current limit to that required. Then turn OFF the power. 

3.

 

Connect your equipment to the unit. Positive polarity to red (+) and negative polarity to black (-). 

4.

 

When ready, turn ON the power supply and then turn ON your equipment. 

5.

 

When finished, turn OFF your equipment and then turn OFF the power supply. 

 
 
SPECIFICATIONS*
 

 

 

 

 

        NP-9615 

 
OUTPUT VOLTAGE: 

 

 

     

 

       0-30V DC 

OUTPUT CURRENT: 

 

 

 

    

           0-5A 

RIPPLE AND NOISE: 

 

 

 

 

       5mV RMS 

LINE REGULATION: 

 

 

 

 

 10mV (±10% variation) 

LOAD REGULATION:   

 

 

 

          30mV 

FIXED VOLTAGE 1: 

 

 

 

          12V DC/ 0.5A (1A peak) 

FIXED VOLTAGE 2: 

 

 

 

           5V DC/ 0.5A (1A peak) 

POWER SOURCE: 

 

 

 

 

 230~250VAC/50Hz 

METER TYPE:   

 

 

 

 

     Digital - LCD 

METER ACCURACY: 

 

 

 

 

     1% + 2 digits 

COOLING SYSTEM: 

 

 

                

           Fan 

CE APPROVAL:  

 

 

 

 

EN61558, EN55014 

DIMENSIONS (W x H x D): 

 

       

              205 x 115 x 280 mm 

WEIGHT: 

 

 

 

                              Approx. 6.5Kg 

 
 
 
 
*Specifications subject to change without notice. 