9
2. Open natural supply tank valve.
3. Make sure control knob of heater is
in the OFF position.
4. Check all joints from equipment
shutoff valve to control valve
( S L 2 8 0 T YA s e e F i g u r e 9 . 1
SN280TYA see Figure 9.2).
Apply mixture of liquid soap and
water to gas joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating
Heater).Check all other internal
joints for leaks.
7. Turn off heater (see To Turn Off
Gas to Appliance).
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only parts
specifically approved with this heater
may result in property damage or
personal injury.
CAUTION: After installation
and periodically thereafter, check to
ensure that no flame comes in
contact with any log. With the heater
set to HIGH, check to see if flames
contact any log. If so, reposition logs
according to the log installation
instructions in this manual. Flames
contacting logs will create soot.
INSTALLING LOGS
It is very important to install the logs
exactly as instructed. Do not modify
logs. Only use logs supplied with
heater.
Place log set on grate to fit as illus-
trated in Figure 10.
Make sure log sits flat on firebox
floor (see Figure 10).
IMPORTANT: Make sure log does
not cover any burner ports (see
Figure11).
Also see placing instruction pgs.
21.
Figure 10 -Installing Log Set
Figure 11 -Installing Log Set (Top View)
Figure 9.2 -Checking Gas Joints
Natural
Gas Meter
Log set
Firebox Floor