background image

1

SN280TYA

SL280TYA

      WA R N I N G :    I f     t h e     i n f orm a t i o n     i n  this
manual  is  not  followed  exactly, a     f i r e     o r
e x p l o s i o n     m a y     r e s u l t  in causing  property
damage,  personal injury,  or  loss  of  life.

    WARNING:   This  is  an  unvented gas-fired
heater.  It  uses  air  (oxygen) f r o m     t h e     r o o m
i n     w h i c h     i t     i s  installed.  Provisions  for
adequate combustion  and  ventilation  air  must
b e     p r o v i d e d .     R e f e r     t o    A i r     F o r  Combus-
tion  and  Ventilation section on  page  4  of  this
manual.

        WA R N I N G :     I m p r o p e r       i n s t a l l a t i o n ,
adjustment, alteration, service  or  maintenance
can  cause  injury  or  property  damage. Refer  to
this  manual  for  correct  installation  and opera-
tional  procedures.  For  assistance  or  addi-
tional  information  consult  a  qualified installer,
service  agency,  or   gas  supplier.

This  appliance  may  be  installed  in  an  aftermar-
ket*  permanently  located, manufactured
(mobile) home, where  not  prohibited  by  local
codes.
This appliance  is  only  for  use  with  the  type  of
gas  indicated  on  the  rating  plate. This
appliance  is  not  convertible  for  use  with  other
gases.

*Aftermarket: Completion  for  sale, not  for  purpose  of
resale,  from  the  manufacturer.

Table  of  Contents

Safety Information Warnings.....................................2

Air For Combustion & Ventilation............................4

Installation....................................................................6

Installing Logs.............................................................9

Operation Heater........................................................11

Specifications.............................................................13

Troubleshooting........................................................14

Parts Breakdown & Parts List..................................17

Log Placing Instructions..........................................21

OWNER’S OPERATION AND INSTALLATION MANUAL

FREE STANDING  LP.&  NATURAL

 GAS  VENT-FREE  STOVE

Do  not  store,  or  use  gasoline  or  other  flammable
vapors  and  liquids  in  the  vicinity  of  this  or  any
other  appliance.
WHAT  TO  DO  IF  YOU  SMELL  GAS

 

Do  not  try  to  light  any  appliance.

 

Do   not   touch   any   electrical   switch;  do  not

       use  any  phone  in   your  building.

 

Immediately   call   your  gas  supplier  from  a

       neighbor’s   phone.   Follow   the   gas  supplier’s
       instructions.

 

If   you   cannot  reach  your  gas  supplier, call

       the  fire  department.
Installation  and  service  must  be  performed  by  a
q u a l i f i e d     i n s t a l l e r ,   s e r v i c e     a g e n c y    o r     g a s
supplier.

Installer : please leave these instructions with
the consumer

WATER VAPOR: A  BY-PRODUCT OF UNVENTED ROOM

HEATERS

Water vapor is a by-product of gas combustion.An
unvented room heater produces approximately one
(1)ounce (30 ml) of water for every 1,000BTU’s
(.3KW’s) of gas input per hour, refer to page 6.

Consumer : please retain these  instructions for
future use

CINTINENTAL APPLIANCE INC

5 Musick   

      

 4600 Highlands  Parkway S.E

.

Irvine             

Suite  #  D/E

CA  92618

        

Smyrna, GA 30080

TOLL-FREE NUMBER: 1-877-886-5989

Summary of Contents for SL280TYA

Page 1: ...Safety InformationWarnings 2 Air For Combustion Ventilation 4 Installation 6 InstallingLogs 9 OperationHeater 11 Specifications 13 Troubleshooting 14 Parts Breakdown Parts List 17 LogPlacingInstructio...

Page 2: ...from combustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use...

Page 3: ...69 This heater is designed for vent free operation State and local codes in some areas prohibit the use of vent free heaters UNPACKING 1 Remove top inner pack 2 Tilt carton so that stove is upright 3...

Page 4: ...You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms wi...

Page 5: ...room unconfined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be...

Page 6: ...ir exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too...

Page 7: ...the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap see joint pipe wrench flexible gas hose check local code...

Page 8: ...ture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly CAUTION To avoid damage to regulator hold gas...

Page 9: ...or personal injury CAUTION After installation and periodically thereafter check to ensure that no flame comes in contact with any log With the heater set to HIGH check to see if flames contact any log...

Page 10: ...ol knob onto output shaft of operation control housing see figure 16 Place operation control housing just inside control compartment door in front of stove see Figure 17 13 Using two black screws pro...

Page 11: ...t step 5 Turn control knob counterclock wise to the PILOT position Press in control knob for five 5 seconds see Figure 18 Note You may be running this heater for the first time after hooking up to gas...

Page 12: ...High Flame WARNING Turn off heater and let cool before cleaning CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas...

Page 13: ...ne LP Ignition Piezo Manifold Pressure 8 0 W C Inlet Gas Pressure In of water Maximum 14 Minimum 11 SN280TYA Btu Variable 20000 28000 Gas Type NG Ignition Piezo Manifold Pressure 3 0 W C Inlet Gas Pre...

Page 14: ...s company B Clean ODS pilot see Cleaning and Maintenance or replace ODS pilot assembly 6 Replace thermocouple 7 Replace control valve POSSIBLECAUSE 1 Ignitor electrode positioned wrong 2 Ignitor elect...

Page 15: ...flame holes blocked 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance or replace burner orifi...

Page 16: ...ce control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections page 8 1 This is common with most heaters If noise is excessive contact q...

Page 17: ...1 7 ILLUSTRATED PARTS BREAKDOWN SN280TYA SL280TYA 1...

Page 18: ...1 8 PARTS LIST SN280TYA SL280TYA This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 13 of this manual...

Page 19: ...1 9 ILLUSTRATED PARTS BREAKDOWN SN280TYA SL280TYA...

Page 20: ...2 0 This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 13 of this manual PARTS LIST SN280TYA SL280TYA...

Page 21: ...e drawings to put log sets in place to the gas pedestal stove indoor vent free NOTICE THE POSITION OF THE LOGS SHOULD AVOID FLAME 1 Take out the paper liner See DRAWING 1 2 Take away the screen from t...

Page 22: ...in on the upper part of log 5 into the pinhole on the left side of log 2 Place the lower part of log 5 on the flat roof at the left side of log 4 See Figure 4 2 Fasten log 4 separately on the correspo...