Procom RD-C Instruction Manual Download Page 18

 

18 

REPLACEMENT PARTS 

 
 

NOTE: 

Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. 

 

PARTS UNDER WARRANTY  

Contact authorized dealers of this product. If they can

t supply original replacement parts, call Customer Service toll free 

at (1-877-886-5989) for referral information.  
 
When calling Customer Service or your dealer, have ready: 

·

 

Your name 

·

 

Your address 

·

 

Model and serial number of your heater 

·

 

How heater was malfunctioning 

·

 

Type of gas used (Propane/LP or Natural gas/NG) 

·

 

Purchase date 

·

 

Usually, we will ask you to return the defective part to the factory 

 

PARTS NOT UNDER WARRANTY  

Contact authorized dealers of this product. If they can

t supply original replacement part(s) call Customer Service toll free 

at (1-877-886-5989) for referral information. 
 
When calling Customer Service have ready: 

·

 

Model number of your heater 

·

 

The replacement part number 

 
 

Summary of Contents for RD-C

Page 1: ...use with other gases Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not...

Page 2: ...ly before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS ITEM NO RD C Input Rating 20000 BTU Hr 20000...

Page 3: ...nge to this fireplace or its controls can be dangerous WARNING Do not allow fans or any other drafts that alter burner flame to blow directly into the heater They create drafts that alter burner flame...

Page 4: ...iar with all precautions required and that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sen...

Page 5: ...tructions to insure proper fresh air for this and other fuel burning appliances in your home PRODUCING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANSI Z 223 1...

Page 6: ...u ft 51 2 or 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater ______________Btu Hr Gas water heater ______________Btu Hr Gas fu...

Page 7: ...r use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your primary heat source If you have a central heating system you may run system s circu...

Page 8: ...talled INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge conn...

Page 9: ...into gas piping and or fittings NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas CAUTION Two gas line installation at the same time is forbidden You are not allowed to o...

Page 10: ...ap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening gas supply tank valve 4 Check all joints of gas supp...

Page 11: ...Check all joints from gas meter to equipment shutoff valve see Figure 11 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks immediately FASTENING HEA...

Page 12: ...firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall are as between studs or solid walls concrete or masonry 1 Drill holes at marked locat...

Page 13: ...attery with the anode pointing out Replace cap 3 Make sure equipment shutoff valve is fully open 4 Turn control knob clockwise to the OFF position See Figure 17 5 Wait five 5 minutes to clear out any...

Page 14: ...m may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any comfort level bet...

Page 15: ...ir though the ports slots and holes in the burner Also clean the pilot assembly A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole abou...

Page 16: ...rol knob for 30 seconds to remove air Repeat igniting operation until air is removed 4 Clean ODS pilot see Cleaning and Maintenance page 15 or replace ODS pilot assembly 5 Check inlet gas pressure or...

Page 17: ...rs of operation Heater produces a whistling noise when burner is lit 1 Turning control knob to HIGH 5 position when burner is cold 2 Air in gas line 3 Air passageways on heater are blocked 4 Dirty or...

Page 18: ...r Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we w...

Page 19: ...T NUMBER DESCRIPTION QUANTITY 1 RV83F1 L S REGULATOR 1 4 W20DT023 ODS OUTLET TUBE 1 1 5 HHY 00 SELECTION VALVE 1 6 W20DT020 OUTLET TUBE 1 7 W20DT022 ODS OUTLET TUBE 2 1 8 W20DT021 ODS INLET TUBE 1 9 W...

Page 20: ...1 4 W20DT004 UPPER GLASS RETAINER 1 5 W20DT014 LOWER GLASS RETAINER 1 6 W20DT006 FLAT GLASS 1 7 W20DT140 REFLECTOR ASSEMBLY 1 8 W20DT200 BURNER ASSEMBLY 1 9 W20DT005 TOP PANEL 1 10 W20DT009 BOTTOM PA...

Reviews: