Procom MGT10BF Owner'S Operation And Installation Manual Download Page 27

www.usaprocom.com

27

200272-01A

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these acces-

sories, contact ProCom Heating, Inc. at 1-866-573-0674 for information.

EQUIPMENT SHUTOFF VALVE

For all models. Equipment shutoff valve with 

1/8” NPT tap.

SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact 

ProCom Heating, Inc. at 1-866-573-0674.
When calling, please have your model and serial numbers of your heater ready.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts 

replaced under warranty.

PARTS UNDER WARRANTY 

Contact  authorized  dealers  of  this  product. 

If  they  can’t  supply  original  replacement 

parts,  call  Customer  Service  toll  free  at

 

1-866-573-0674 for referral information.
When calling Customer Service or your dealer, 

have ready:
•  Your name
•  Your address

•  Model and serial number of your heater
•  How heater was malfunctioning
•  Type of gas used (Propane/LP or Natural 

gas/NG)

•  Purchase date
Usually, we will ask you to return the defective 

part to the factory

PARTS NOT UNDER WARRANTY

Contact  authorized  dealers  of  this  product. 

If  they  can’t  supply  original  replacement 

part(s)  call  Customer  Service  toll  free  at

 

1-866-573-0674 for referral information.

When calling Customer Service have ready:
•  Model number of your heater
•  The replacement part number

Summary of Contents for MGT10BF

Page 1: ...cal switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire d...

Page 2: ...s manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For a...

Page 3: ...re more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NATURALAND P...

Page 4: ...s may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect...

Page 5: ...Heater Weight 16 5 lbs 22 lbs Shipping Weight 19 4 lbs 26 7 lbs Model MGT30BF Ignition Piezo Ignitor Gas Type Natural Gas Propane Gas BTU Hr Input Max available 30 000 30 000 BTU Hr Input Min availab...

Page 6: ...ew York NY 10018 National Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02269 9101 This heater is designed for vent free op eration State and local codes in some areas prohibit the use...

Page 7: ...e combustion and ventilation air Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever...

Page 8: ...nto adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From...

Page 9: ...igure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may...

Page 10: ...ped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Attach m...

Page 11: ...bracket is firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at mar...

Page 12: ...talling Bottom Mounting Screws Installing Wall Spacers 1 Place heater on wall mounting bracket 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting scre...

Page 13: ...of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator Thisisnormal Whenthein let connection fitting is inserted...

Page 14: ...the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tight...

Page 15: ...ator between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regulat...

Page 16: ...ulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sedimen...

Page 17: ...ONS 5 Correct all leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 1 Open equipment...

Page 18: ...2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you smell...

Page 19: ...old match to pilot until pilot lights 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a...

Page 20: ...lectrical Outlet ELECTRICAL WIRING Any electrical re wiring of this appliance must be done by a qualified electrician This wiring must be done in accordance with local codes and or in Canada with the...

Page 21: ...which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARNING If yellow...

Page 22: ...minutes 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front pan...

Page 23: ...as well as the fan heater is recommended For heavy or continuous use periodic cleaning must be done more frequently If the heater blows alternating cold and warm air check the fan for free movement an...

Page 24: ...is clogged 5 Incorrectinletgaspressureorin let regulator setting is damaged 6 Control knob not in PILOT position 7 Depleted gas supply pro pane 1 Turn on gas supply or open equipment shutoff valve 2...

Page 25: ...Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 or replace burner orifice 2 Replace burner orifice 3 Contact local gas supplier Delayed ignition of burner s 1 Ma...

Page 26: ...carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces un wanted odors 1 Heater is burning vapors from...

Page 27: ...our model and serial numbers of your heater ready REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARR...

Page 28: ...www usaprocom com 200272 01A 28 PARTS MODEL MGT10BF 2 10 3 1 8 7 5 6 9 13 12 11 4...

Page 29: ...02 Mounting Bracket 1 3 ML083 04 Piezo Ignitor 1 4 STL1001 Thermostat Valve Assembly 1 5 Burner Assembly 1 6 ND0310A MU 600 PI4 ODS Pilot 1 7 RVD88 UB 4 9 Safety Dual Fuel Regulator 1 8 160960 01 Cap...

Page 30: ...www usaprocom com 200272 01A 30 PARTS MODELS MGT20BF AND MGT30BF 10 2 11 3 1 8 7 5 6 9 14 13 12 15 16 4...

Page 31: ...ly 1 5 Burner Assembly 1 6 ND0310A MU 800 PI6 ND0310A MU 800 PI6 ODS Pilot 1 7 RVD88 MAB 4 9 RVD88 MAB 4 9 Safety Dual Fuel Regulator 1 8 160960 01 160960 01 Cap with Seal 1 9 160960 02 160960 02 Inle...

Page 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...

Reviews: