HearthSense
200549-05A
10
Figure 5 - Moving Thermostat Sensing
Bulb
Figure 6 - Removing Front Panel
INSTALLATION
1. Carefully remove bulb clips with ther-
mostat sensing bulb from the shipping
position in the back panel, see Figure 5.
2. Insert bulb clips into 2 rectangular slots
beside the shipping location (relocation
position). If clips are damaged replace with
clips located in the hardware package.
FASTENING HEATER TO WALL
INSTALLING THERMOSTAT SENSING BULB (OPTIONAL)
For Heaters with Blower Installed Only
REMOVING FRONT PANEL
Screw
Front
Panel
1. Remove 4 screws securing front panel.
2. Carefully slide front panel forward.
Mounting Bracket
The mounting bracket is located on back panel
of heater. It has been taped there for shipping.
Remove mounting bracket from back panel.
Methods For Attaching Mounting
Bracket To Wall
Use only the last hole on each end of mount-
ing bracket to attach bracket to wall. Attach
mounting bracket to a wall only in one of two
ways:
1.
Attaching to wall stud:
This method pro-
vides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.
2.
Attaching to wall anchor:
This method
allows you to attach mounting bracket to
hollow walls (wall areas between studs)
or to solid walls (concrete or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.
Thermostat
Sensing
Bulb
Relocation
Location
Thermostat Sensing Bulb Shipping Position
Bulb Clip
Capillary
Thermostat Sensing Bulb