![Procom GEM DC Series Installation Manual Download Page 2](http://html1.mh-extra.com/html/procom/gem-dc-series/gem-dc-series_installation-manual_1608927002.webp)
1. Introduction :
GEM-DC series meters are single phase panel meter with Measurement
of Accuracy class 1.0 (FS), High glow display for distant viewing,
Programmable site selectable Scaling of Current.
2. Model Selection Chart :
3. Technical Specification :
Measurements*
Current
Shunt (DCI)
:
75 mV full scale
Scale (I) :
0-999 A
Voltage
Voltage :
2 - 50 VDC,
6 - 150 VDC,
12 - 300 VDC,
Voltage Withstand : 2 Times Rated Voltage
Resolution
:
4 digit display with auto decimal scrolling
& Polarity sign in GEM-DC-I
Accuracy
:
Class 1
Auxiliary Supply
:
35V - 300V (AC/DC)
0
Temperature
:
-10 to 70 C
0
Storage
:
-20 to 75 C
Humidity (non-condensing)
Upto 85%RH
Mounting
:
Panel Mount
Display
:
4 digit Single Row
GEM-DC-V
GEM-DC-I
DC Voltage DC Current
Installation Guide
Page-1