Signal connections

To preserve RF screening integrity the signal connections to the amplifier should be made

using good quality coaxial cable and connectors. This is particularly important with DTT to

minimise the ingress of impulsive electrical interference. The use of cable ‘benchmarked’

under the CAI scheme is recommended.
Crimp ‘F’ connectors, used in accordance with the manufacturer’s instructions, will give the

best results. The importance of achieving sound braid connections cannot be over-stressed.

System earth bonding

Earth bonding terminals are provided on the amplifier castings for use where necessary.
Distribution systems supplying signals to more than one household should comply with the

safety requirements of BS EN 50083-1.  This effectively requires the system to be earth

bonded. (The use of isolated outlet plates is no longer  recommended since they compromise

screening integrity and allow ingress of interference.)

Fixing

Methods for mounting the amplifier are illustrated in 

Figs. 5 to 7

. The cable tie fixing is

intended to support the weight of the amplifier only. Cables should be taped to the mast at

intervals of approximately 400 mm to ensure that their weight is adequately supported.
Being fully screened, these amplifiers will not be affected by proximity to antennas. However

clearance of not less than 300 mm from the nearest part of an antenna should be observed

to avoid degrading the antenna’s performance.

Fig.5

 cable tie fixing

Fig.6

 fixing to flat surface

Fig.7

  Fixing  the  amplifier

module  directly  (indoor

application  only,  discard

mouldings).

Earth terminal

(see text).

Fig.4

 – combining antennas and LNB

proCOM31VUS

proOUT13 outlet

Fig.2

 – splitting a distribution system feed to separate outlets

proCOM21VU

proOUT11C outlets

amplifier proAMP24

Fig.3

 – using a UHF preamplifier

proCOM21VU

proOUT12C outlet

power unit

proPSU11F

preamplifier

proMHD11L

Note: a preamplifier cannot be powered via the proCOM31VUS since there is no line-power

pass to the UHF port.