Product Working Diagram

Input

Work

Environment

Internet Protocol

None

None

Output

Input

PoE Compliance

Pin Assignment

Output

Data Speed

Operating Temperature

Operating Humidity

Operating Altitude

Storage Temperature

44-57V DC 

IEEE802.3 af

4/5(+),7/8(-) Or3/6(+),1/2(-) Or 3/6(-),1/2(+)

5V  2.0A

None

-20

 To 40

20%-80%

No Condensation

Below2000m

-20

-70

Storage Humidity

10%-90%

No Condensation

Network Transmission

IP Class

CE

65mm×29mm×17mm

IP40

Certificate

Dimensions

Summary of Contents for PT-PTC-A-AF

Page 1: ...PT PTC A AF Ethernet Adaptor WWW PROCETPOE COM Fast Installation Manual Data Code PTD2206002...

Page 2: ...s general garbage Users should dispose of it separately from household waste when throwing i t away Sorting is helpful to save natural resources and reduce environmental pollution Please dispose of in...

Page 3: ...op or can be xed and opened for use The input and output of the device do no t exceed thesafe voltage of 57V and there is no need for electric shock protection TheproducthaspassedtheEUCEcerti ction Th...

Page 4: ...w Light On Normal power supply Light O Abnormal power supply 2 Type C PortOutputPower Supply LEDIndicator Green Light On Normal connection Light O Abnormal connection 3 RJ45 Port 4 Type C Port 1 2 3 4...

Page 5: ...tput Data Speed Operating Temperature Operating Humidity Operating Altitude Storage Temperature 44 57V DC IEEE802 3 af 4 5 7 8 Or3 6 1 2 Or 3 6 1 2 5V 2 0A None 20 To 40 20 80 No Condensation Below200...

Page 6: ...Light On Normal connection Light O Not connected or failed to connect Blinking Data transfer Light On Normal power supply Light O Abnormal power supply FCC CFR47 Part 15 EN 55032 2015 EN 55035 2017 EM...

Page 7: ...6 65MM 29MM 17MM Product Dimensions Pic3 1 Product Dimensions...

Page 8: ...length should be less than 100m 2 Connect one end of the Type C cable to the output port of this product and the other end to the powered device Such as a mobile phone tablet computer etc 3 If you nee...

Page 9: ...part exceeds the limit requirement speci ed in GB T26572 2011 There is currently no mature alternative in the industry which meets theenvironmental protection requirements of the EU RoHS directive Hg...

Page 10: ...se hand it over to a company quali ed for the disposal of waste electronic products Please refer to the national or local regulations on the disposal of WEEE for the correct method Product Quality Cer...

Reviews: