Exclusion of liability 

Illustrations, descriptions as well as the technical specifications conform to the 
instruction manual on hand at the time of publishing or printing. However, Zehntner 
GmbH Testing Instruments policy is one of continuous product development. All 
changes resulting from technical progress, modified construction or similar are 
reserved without obligation for Zehntner to update. 

Some of the images shown in this instruction manual may be of a pre-production 
model and/or are computer generated; therefore the design / features of the 
delivered product may differ in various aspects.  

The instruction manual has been drafted with the utmost care. Nevertheless, errors 
cannot be entirely excluded. The manufacturer will not be liable for errors in this 
instruction manual or for damages resulting from any errors. 

The manufacturer will be grateful at any time for suggestions, proposals for 
improvement and indications of errors. 

© Zehntner GmbH Testing Instruments 

Summary of Contents for ZUA 2000

Page 1: ...ZUA 2000 Universal Applicator Instruction manual...

Page 2: ......

Page 3: ...Options 7 4 Device overview 9 4 1 Setting ranges 10 4 2 Retaining spring 10 5 Handling 11 5 1 Setting the applicator 11 5 2 Manual application 11 5 3 Application using an automatic film applicator 12...

Page 4: ...tner to update Some of the images shown in this instruction manual may be of a pre production model and or are computer generated therefore the design features of the delivered product may differ in v...

Page 5: ...ll safety notes Besides the notes in this instruction manual the generally applicable safety instructions and regulations for prevention of accidents must be observed 2 2 Safety notes and hints The ZU...

Page 6: ...acking you have to inform and hold the courier liable immediately in the following way When opening the parcel we had to notice that etc This superficial checking of the goods has to be done within th...

Page 7: ...icate of manufacturer 1 Carrying case In case of custom made film widths the carrying case might differ from the above or not be provided at all 3 4 Options Custom made film widths and gap heights ZAA...

Page 8: ...alibration and certification Zehntner GmbH Testing Instruments refuses all warranty and liability claims for damages caused by usage of the ZUA 2000 in combination with non original accessories or acc...

Page 9: ...Page 9 4 Device overview 1 Adjusting wheel both side 2 Fixing screw 3 Side plate both sides 4 Side scale both sides 5 Retaining spring both sides 6 Application blade 6 1 2 3 4 5...

Page 10: ...duce a retaining spring which can be used for all of the following applications manual application with ZUA 2000 automatic application with ZAA 2300 and ZAA 2600 heatable application with ZAA 2300 and...

Page 11: ...x the setting 5 2 Manual application Only use on solid substrates such as vacuum plates glass plates test panels test charts or automatic film applicators If necessary adjust the ZUA 2000 as described...

Page 12: ...the ZUA with the mark for the adjusting wheel in order to see the set gap height properly The spring ends without loops should not protrude the side plates After mounting the retaining springs to the...

Page 13: ...r is used the ZUA 2000 can be placed in front of the weight Please make sure that the spring ends without loop are facing the weight Carry out the application as described in the separate instruction...

Page 14: ...nstruments or your authorised Zehntner agent otherwise all guarantee and liability claims are void 6 2 Disassembling and cleaning the applicator The ZUA 2000 must be cleaned immediately after use Depe...

Page 15: ...forcement If the steel reinforcement is soiled so heavily that it does not fall out automatically fasten a screw halfway into the thread of the steel reinforcement and use it to pull out the reinforce...

Page 16: ...t the steel reinforcement into the lower part of the application blade 6 then assemble the lower and upper part of the application blade matching the white dots Screw both adjusting wheels 1 and the f...

Page 17: ...2 36 x 1 58 ZUA 2000 150 200 mm 7 90 240 mm x 60 mm x 40 mm 9 45 x 2 36 x 1 58 ZUA 2000 200 220 mm 8 70 260 mm x 60 mm x 40 mm 10 24 x 2 36 x 1 58 ZUA 2000 220 on request depending on version ZUA 200...

Page 18: ...e Delivery 6 Description 5 Overview 9 E Exclusion of liability 4 Extent of delivery 7 F Features 5 H Handling 11 I Instrument Delivery 6 Description 5 L Liability 4 M Maintenance and cleaning 14 Manua...

Page 19: ......

Page 20: ...Zehntner GmbH Testing Instruments Gewerbestrasse 4 CH 4450 Sissach Switzerland Tel 41 0 61 953 05 50 Fax 41 0 61 953 05 51 zehntner zehntner com www zehntner com Version 2 4 dated 03 05 2017...