background image

• 

Specifications subject to change. | ©2022 Procella Audio Svenska AB, Procella Audio USA, LLC. All rights reserved. | V1.0 2022/11

Maintenance

After operating for some time, if the airflow and cooling become 
less effective, please turn off the amplifier. Remove and clean the 
dust filter and clean this filter. 

2.5 DSP functions

• 

The input delay of each channel is 30ms, the output delay is 

20ms, and the step is 0.01ms

• 

Audio input level ma - 18db

• 

4x4 audio route mixing, mixing ratio - 80dB ~ + 18db

• 

8-segment input parametric EQ, 5-segment output parametric 

EQ, high-low pass filter

• 

Support FIR filters of order 512 and below

• 

Volume, mute, phase adjustment, mode selection

• 

Output average, peak voltage limiter

• 

Parameter saving / retrieval between machines

• 

Speaker parameter configuration

• 

User / Debug / Factory permission setting

3. Carton Contents

The DA08-DSP amplifier is shipped in a cardboard carton 
containing the amplifier unit, a mains cable appropriate for the 
sales territory and a document pack. 

The full contents are listed below:

• 

Procella DA08-DSP amplifier

• 

Mains power cable 

• 

Adhesive rubber feet x 4

• 

Document pack

4. Installation

The installation and equipment rack should be configured to 
provide appropriate ventilation airflow space around the front and 
rear of the amplifier as illustrated 

Diagram 1b

. A ventilation airflow 

space of at least 25 mm (1 inch) should be maintained along at 
least one side of the amplifier at all times. Ventilation apertures 
are located on the rear panel of the amplifier and must not be 
obstructed. It is important to retain at least 80 mm (3.1 inch) free 
space for airflow behind the amplifier rear panel.

The amplifier works in a 0°C~40 environment. Airflow goes from 
the front of the amplifier (ventilation holes) through the rear panel 
to ensure effective heat dissipation. Please ensure that the air can 
flow from the front to rear panels. 

Note

If the internal temperature exceeds 85 degrees C, the output 

voltage will be reduced, to avoid excessive temperature rise. If the 
temperature continues to rise to 90 degrees C, the power amplifier 
will shut down. Once the temperature has dropped to a safe 
temperature, the amplifier will restart automatically.

Overview

Diagram 1b

Summary of Contents for DA08-DSP

Page 1: ...ecifications subject to change 2022 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2022 11 DA08 DSP Power Amplifier User Manual V1 0 https procella audio contact procella au...

Page 2: ...or output ancillary equipment may invalidate support warranty or guarantees of performance 5 These amplifiers are intended to be installed and operated indoor in a controlled environment within an amb...

Page 3: ...e apparatus 14 Do not unplug the unit by pulling on the cord use the plug 15 Only use attachments accessories specified by the manufacturer 16 Unplug this apparatus during lightning storms or when unu...

Page 4: ...tching power supply adopts active Power Factor Correction and soft switching technology and is optimized for audio amplification Bridge pairs of channels 1 2 and or 3 4 to increase power by a factor o...

Page 5: ...ents are listed below Procella DA08 DSP amplifier Mains power cable Adhesive rubber feet x 4 Document pack 4 Installation The installation and equipment rack should be configured to provide appropriat...

Page 6: ...power 6 Fans Provide front to back forced airflow for cooling 7 Output sockets 8 Ethernet connection 9 XLR inputs 4 1 Attention In order to achieve the best performance and the highest reliability pl...

Page 7: ...Specifications subject to change 2022 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2022 11 4 3 Menu structure of screen display Operating instructions...

Page 8: ...annel Display the machine operating temperature network status and current selected preset Main screen The following functions can be controlled through the main screen Press the rotary encoder to ent...

Page 9: ...ays Saving Off Saving close after 2 minutes IP Mode Auto DHCP User set DHCP or maual settings Amp IP 192 168 1 10 Can be changed in manual mode Factory Reset 5 Monitor V Output voltage of each channel...

Page 10: ...P for all channels Level Parametric eq Delay matrix limiter FIR filter Signal To Noise Ratio 105 dB default gain A weighted 20 Hz 20 kHz 8 THD N typical 0 05 20 Hz 20 kHz 8 load 3 dB below 10 rated po...

Page 11: ...e center with all transportation and insurance charges prepaid All warranties of whatever character are void and unenforceable if the component or any part thereof is not purchased from an authorized...

Page 12: ...Specifications subject to change 2022 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2022 11...

Reviews: