6
5
ELECTRICAL PROPERTIES
5.1
ELECTRICAL
CHARACTERISTICS
WARNING
Loads above the electrical parameters can cause permanent damage. Permanent loading of
the system with absolute maximum values can influence the reliability and lifetime of the
system.
It is therefore recommended to operate the system only within the range of the nominal
specification.
The system may only be connected to chargers approved by Probst GmbH that comply
with the performance data of the product.
The following tables show the electrical specifications of the battery system. Table 3 shows the
performance-related characteristics of the system.
Designation
Stand-Alone
Increase in performance
Number of systems
1
2
Voltage range of the
battery system
37.8 V - 58.8 V
Nominal voltage
25,2 V
Capacity
104 Ah
208 Ah
5,200 Wh
10,400 Wh
Recommended discharge
depth
15 %
to
90 %
of nominal capacity
Discharge current Continuous
75 A
135 A
Discharge current
10 s Peak load1
250 A
450 A
Charge current/recuperation
Continuous1
50 A
90 A
Recuperation current 10
s Peak load1
100 A
145 A
Table 3: Electrical properties (single system)
under normal conditions
1Power reduction
depending on temperature and state of charge. Information on this in the parameter list
The maximum number of parallel connections is 4 systems.
The following table shows the maximum permissible current values set by the factory as a
function of the state of charge and temperature. The term
charging
stands for both charging
and recuperation.
Summary of Contents for VM-301-KJ-GREENLINE
Page 16: ...General 15 43 51500024 V2 GB 3 2 Survey and construction...
Page 41: ...Maintenance and care 40 43 51500024 V2 GB 7 2 Lubrication plan...
Page 42: ...Maintenance and care 41 43 51500024 V2 GB...
Page 45: ......
Page 47: ......
Page 69: ......