Operation
15 / 20
5310.0411
V2
GB
5.2
Adjusting of the dead Point
Overjump securing of the dead point
If the gripping range is adjusted correct according to chapter "Adjusting of the gripping range", the stop nut (see
picture 5) must be adjusted, in lifted condition of the device (with gripping good).
The
distance
between threaded rod and stop nut
must be always
adjusted (with lifted load) to the
measure of
60±2
mm (fig. 5)!
Fig. 5
To ensure a symmetrical adjustment of the
gripping arms, check if the spreader bar goes
parallel (
≡
) to upper part of the device.
Fig. 6
6
Operation
6.1
General
•
Connect the device (BSZ-KH) with the support frame.
•
Clean
the
rubber grippers
before using the device and
check
them for
abrasion
.
•
Clean absolutely heavily dirty gripping goods at the working surfaces of the rubber grippers before the
gripping procedure!
•
Lower the device (BSZ-KH)
in the middle or in the center of gravity
on the gripping good. Take care, that the rubber
grippers seat on the gripping good, that the clamps is relieved and the automatic release can release.
•
Lift the device (BSZ-KH) careful with the support frame, so that the device clamps of the device close themselves.
•
A constant load distribution and a optimum cohesion of the grippers is a indispensable supposition for a secure
operation with the device and must be checked anytime.
•
Transport the device with the gripped load careful to the place of destination.
•
Deposit the gripping good with the device on the ground. Lift the device and it opens automatically, the automatic
release locks, so that the device can be lifted without the gripping good.
Spreader
bar
60±2
mm
Stop nut