![probst 5220.0011 Manual Download Page 28](http://html1.mh-extra.com/html/probst/5220-0011/5220-0011_manual_1608367028.webp)
Operating
JUMBO-BV-VARIO-B
V2
26/07/16
27 / 40
6.3
Adjusting the hovering position
6.3.1
Adjusting the hovering position without load
Open and remove both snap hooks off the vacuum hose
corset in order to release the vacuum hose unit (for
vacuum operation).
Vacuum hose is now released.
The hovering position without load must be adjusted with each operation.
The hovering position of the lifting device must be adapted to the weight of the vacuum head.
A valve (2) in the tube support cylinder is used to adjust it.
When you apply the vacuum head to the load a valve is fully opened by a plunger and the valve rod in the
vacuum head. The load can be sucked and lifted.
Adjustment:
Turn the adjustment screw (1) at the operating unit (accessible from the bottom).
Turn clockwise (direction of arrow)
Valve becomes opened.
Turn counter-clockwise
Valve becomes closed.
The farther the valve is opened the lower the device hovers.
When the valve is closed totally the device bounce up abruptly as soon the blower is switched on!