pg. 35
Operator’s Manual,
Ranger Gunite r1.0
The hydraulic oil temperature is reaching a critical limit and should be monitored. Check to ensure the
cooler is running and oil levels are sufficient.
Cement low-level sensor activated. Must override to continue (see Mixer Control
–
page 13
). To bypass
this alarm temporarily the operator can select level over-ride on the mixer control screen.
Gate position alarm. The gate position is outside the tolerance allowed based on the selected mix gate
position. To bypass this alarm the operator can select gates over-ride on the mixer control screen. The
mixer will begin a start count and end count that shows when this gate setting was overridden. This will
be logged in the mix log.
Gate level alarm. The sand bin is empty or the gate material sensor needs to be calibrated (teach) the
trigger point/bottom of the gate. A teach switch is located on the main power distribution box. Set the
gate all the way down to the belt and hold the teach switch until the sensor amber light flashes and stops.
To bypass this alarm temporarily the operator can select level over-ride on the mixer control screen.
Low grease alarm. If the mixer is equipped with an automatic grease system then the grease level is low
and needs to be topped up. To bypass this alarm temporarily the operator can select level over-ride on
the mixer control screen.