INSTALLATION & WIRING

Installation / Wiring

Remember 

Wireless Range

Range between the sensor and the Master Thermostat is approximately 100 feet with no 

obstructions and approximately 50 feet in standard residential metal, brick, and concrete construction. 

Drill a 3/4” hole in the supply duct at least 

36” from heat exchanger/coil and before 

the first zone damper, in relation to 

airflow.

Remove cover and Wire R and C to the 

24V equipment transformer. (with power 

off)

Mount on supply duct, leaving covers off 

for linking procedure, if needed.  (If 

supplied in 2 Zone Kit it will already be 

linked).

The Sensor must be powered with 24 

VAC.  We recommend wiring it to the 

equipment board. 

1.

2.

3.

4.

Our Wireless Zoning System contains 

selectable wireless communication.  

Each component has a jumper switch 

labeled FSK and ASK.  Default setting: FSK.  

All components must be set to the same 

position for wireless communication. 

This selectable communication option is 

available to you in case you have a device 

you are pairing with that only has the 

ASK option.