Select
HEAT or COOL using the system key. You have to program heat and cool each separately.
Press
MENU
Press
SET SCHED
Note: Monday is displayed and the WAKE icon is shown. You are now programming the WAKE
time period for the Monday setting.
Time is flashing. Use the or key to make your time selection for the Monday
WAKE
time period.
Note: If you want the fan to run continuously during this time period, select ON with
the
FAN key.
Press
NEXT STEP
The setpoint temperature is flashing. Use the or key to make your setpoint selection for
the Monday
WAKE period.
Press
NEXT STEP
Repeat steps 4 thru 7 for Monday
LEAVE time period, for Monday RETURN time period, and for
Monday
SLEEP time period.
1.
2.
3.
4.
5.
6.
7.
8.
Monday
Repeat steps 4 thru 7 for the remaining days of the week.
Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday
PROGRAMMING THE THERMOSTAT
6
To customize your 7 day program schedule, follow these steps:
Set 7 Day Program Schedule
Additional step if R251W indoor remote sensor is connected.
The
T955W master thermostat will either average all sensors (system average) or only use
one sensor for the system ambient temperature (priority). The default setting is
SYSTEM
AVERAGE, which means all sensors are averaged to create the system average ambient
temperature reading. The
NEXT ZONE key can be pressed to change the priority.
The system information area of the display shows the priority.
For Example:
There is an
R251W connected and it is named REMOTE 1. If the NEXT
ZONE key is pressed until REMOTE 1 is shown, then the REMOTE 1 ambient temperature
reading will be used exclusively for that time period. All other sensors will be ignored.