X K 3 1 9 0
–
DS3
(17)
Chapter Five Information Cue
I. Regular information cue:
1. means:Please wait, the indicator is conducting internal calculation. Do not carry
out any operation now.
2. Prnt means: Please wait; data is transmitted between the indicator and printer.
3. LoAd means: Data save. It will be displayed for less than two seconds for giving a cue
to the operator.
II. Error operation information cue:
1. Err 03 means: overload alarm, all or part of the load must be unloaded at once.
2. Err 08 means: No matched record is found or inquiry condition is wrong.
3. Err 10 means: Vehicle numbers saved are more than 1000.
4. Err 17 means: Parameter setting does not meet the requirement, please reset it.
5. Err 19 means: Printing cannot be conducted in occasion of zero or negative weighing,
unstable weighing or unfulfilled zero reset condition.
6. Err 28 means: When the print date is earlier than that saved in weighing record, please
reset date and clear all record.
III. Error connection information cue:
1. Err P means: Error printer connection or printer fault. Press any key to exit and
re-connect the printer or replace it with another one.
2. Erd ** means: The digital load cell with address “**” has communication failures.
(1) If this is a scale in use, we may judge whether there is a connection failure or the
communication interface of load cell is damaged.
(2) If this is the scale is not debugging, you can check according to the following command
a. Check carefully if the connection wire of load cell is connected properly.
b. Check if address of load cell is right without replication.
c. Please re-set the quantity of load cells.
IV. Information cue of components and parts failure and elimination methods
1. Err 18 means: The keyboard fails. This will be displayed for 10 seconds before entering
into weighing displaying page. The keyboard shall be replaced.
2. Err 20 means: a part of the data in RAM has been lost. Plug the calibration socket into
the indicator and restart it for self-check. After this, without finding the
occurrence of Err 20, the calibration socket may be unplugged.
3. Err 21 means: RAM and E
2
PROM calibration data are data lost. Please plug the
calibration socket, re-enter the original calibration data and restart the indicator
or conduct calibration again.
4. Err 22 means: RAM destroyed; please replace it with a new chip and then conduct
calibration again.
5. Err 23 means: E
2
PROM destroyed; please replace it, re-enter the original calibration