Maintenance
1. If the pressure is not enough or too large, please adjust pressure adjuster, (+) to increase
the pressure, (-) to reduce the pressure.
2. If the printed color not equality or the adhesion not good? First check the right set of
temperature and the time, and increase the pressure.
3. If it is cold-ripping transfer paper, please use blackboard wiper to rub against the whole
transfer paper, wait for 5-10 seconds, then rip off the transfer paper. If it is the hot-ripping
transfer paper, you can rip off immediately after printing.
4. Timer: When the time is over, the buzzer does not work or out of order, check the contact
of the sensitive switch at the tail of machine. If it is not proper, adjust it to proper position.
5. If any quality problem please contact our company.
PLEASE NOTE: Successful print requires right time and temperature and pressure, the
thickness and material of the cloth, even type of transfer paper and inks.
1. Temperature Setting: press SET key, temp flashes, press ^ key to increase the set
temperature, and press “v” key to reduce the set temperature;
2. Press the set key again, the time flashes, press the ^ key to increase the setting time, and
press the “v” key to reduce the setting time;
3. Counter function: Finished one transfer, counter display plus 1. Press and hold CLEAR for
more than 3 seconds to clear the counter count value.
4. Adjust the “Working pressure adjuster” to set the working pressure.
5. Place the cloth on the down board, cover the printing paper ,(please note the right
surface of the paper), when the temperature ready, press the handle down .
6. When the temperature is reached, press your transfer.
7. When finish, Turn off the machine.
Note:
1. Setting of control parameters: Long press the SET key for more than 4 seconds to enter
the parameter setting. The parameter code is displayed in the PV window and the
parameter value is displayed in the temp window. Press thekey or key to adjust the
parameters to the required value. Press the set key once to switch each control parameter
and the parameter prompt (see the list of control parameters for details). Press thekey or
key to modify the parameters to the required value. Long press the set key for more than 4
seconds or 1 minute without any key action, it will automatically return to the working
indication state.
2. Click the clear key to select the temperature and time values of different PN segments.
The segment number is on the right of counter. The maximum 1-9 segments are available,
and the default is 5 segments. Different sections correspond to different temperature
settings and countdown time values.