background image

4.1 Switch The System On

4. Turn On The System

5.1 Press the Mode Select button located 

in the center of the Control Panel.“Set 

Temp” lights located in the display will 

illuminate indicating you are in the adjust 

temperature mode.

5. Adjusting The Temperature

5.2  Next, press the (-) button located to 

the bottom of the Mode Select button to 

lower the temperature setting,or press the 

(+) button located to top of the Mode 

Select button to raise the temperature 

setting.The temperature can be set from 

170° F (76° C) to 430° F (220° C).

6. Adjusting The Time

6.1 Once you have adjusted the 

temperature, press the Mode Select button 

again. “Set Time” lights located in the 

display will illuminate indicating you are in 

the adjust time mode.

6.2 Next, press the (-) button located to the 

bottom of the Mode Select button to lower 

the value ,or press the (+) button located 

to top of the Mode Select button to raise 

the time value .The time setting range can 

be set from 0~999.

7. Adjusting The Time

7.1 Once you have get your target Temp., 

press the “SET” button again. “Set Time” 

lights located in the display will illuminate.

8. Counter Setting

8.1 Once you have adjusted the time, press 

the Mode Select button again. “Counter” 

lights located in the display will illuminate 

indicating you are in the counter setting 

mode.

8.2 Next, press the (-) button to lower the 

value ,or press the (+) button to raise the 

value .The counter setting range can be set 

from 0~999.

0~999.

Summary of Contents for TransPro Plus 1620

Page 1: ...HEAT PRESS USER S GUIDE www ProWorldInc com Pro World Inc 961 Bethel Ave Pennsauken NJ 08110 Toll Free 800 678 8289 Outside U S 856 406 1020 Fax 856 406 1025 ...

Page 2: ...f the machine in the right position 1 2 Fasten the control box onto the machine with 4 screws tightly 1 3 Connect 5 phase aviation plug and 2 phase aviation plug then fasten tightly ATTENTION The aviation plug must be connected tightly CAUTION A sway connector will cause aviation plug burning under heavy electricity www proworldinc com ...

Page 3: ...d CAUTION Failure to follow these instructions will cause 1 Erratic controller functions 2 Inaccurate displays slow heat up 3 The circuit breaker to disengage NOTE If the supply cord is damaged it must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid hazard 3 ChangeToAutoMode ManualMode 3 1 Turn around Ramspin system into picture position machine ...

Page 4: ...ton again Set Time lights located in the display will illuminate indicating you are in the adjust time mode 6 2 Next press the button located to the bottom of the Mode Select button to lower the value or press the button located to top of the Mode Select button to raise the time value The time setting range can be set from 0 999 7 AdjustingTheTime 7 1 Once you have get your target Temp press the S...

Page 5: ...played Readout will be on a scale of 0 9 A 0 Pressure readout would indicate no pressure at all and 9 would indicate very heavy pressure 10 Printing Pressing Once your equipment has reached the designated temperature Position the garment and application and proceed to press Lower and lock the heat platen into the press position This procedure will start the automatic timing process The timer will ...

Page 6: ... seconds display shows LCK 12 2 Input 68 then press set button to enter into second level menu 12 3 Press set button to select Pb mode Press up and down button to make tem perature calibration 12 4 Press set button 4 seconds to quit Note If temperature on heat platen is higher than circuit board shows pls raise the Pb value Example Heat platen temperature 190C Circuit board temperature 185C Pls se...

Page 7: ...tton for 4 seconds display shows LCK 13 2 Input 68 then press set button to enter into second level menu 13 3 Press set button to select Pb mode Press up and down button to make tem perature calibration 13 4 Press set button 4 seconds to quit ...

Page 8: ...er Platen Yes Power 120volt 1800W 16 4Amps Power 240volt 1800W 8 2Amps Temperature Range Max 221 430 Heating Up Time 180 20minutes Time Range 0 999S Way To Change Lower Platen Ramlock quick change system Machine Size open size 29 5 x16 9 x39 3in Packing Size 33 1 x20 5 x23 4 in Packing Weight 119 0lbs Certificate CE FCC ...

Page 9: ...t Board 1800353 1 Magnet switch 1800620 1 Magent 1800609 1 Control box base 1200685 1 16 5 phase aviation plug Female with wires welded 1800955 1 17 2 phase aviation plug Female with wires welded 1800962 1 18 Machine handle 1200581 2 Machine handle 1200395 2 19 Machine arm 1200583 2 Machine arm 1200409 2 20 Washer 20 13 15 2000296 2 21 Lift links 1200140 2 Lift links 1200139 2 23 Machine body 1200...

Page 10: ...1200074 1 34 Handle shaft 1200145 1 35 Foam Grip 1200645 1 36 Screw M8 16 1901071 1 37 Adjustment spindle base 1800142 1 38 Adjustment spindle female 1901072 1 39 Adjustment spindle male 1901073 1 40 Thermocouple 1800281 1 42 Balance screw 1901074 1 43 Thermosat 1800133 1 44 Lower platen 1800802 1 Lower platen 1800388 1 45 Adjustment knob 1800479 1 46 Silicon pad 1800422 1 Silicon pad 1200539 1 47...

Page 11: ...1 Ramlock base 1200958 1 2 Ramlock locking sheet 1200960 1 3 Ramlock locking set male 1200961 1 4 Ramlock locking screw 1900959 1 5 Ramlock handle 1200956 1 6 Ramlock locking set female 1200957 1 Technical Parameters Cont RamlockSystem ...

Page 12: ...WIRING SCHEMATIC www proworldinc com ...

Page 13: ... is solely the responsibility of the customer Prior to 30 days the shipping costs will be refunded if Pro World deems the equipment to be defective as stated Pro World cannot be held responsible for improper handling or any other damage incurred in transit No charge will be made for labor and components for repair of in warranty equipment OUT OF WARRANTY machines will be charged at the repair rate...

Page 14: ...www ProWorldInc com Pro World Inc 961 Bethel Ave Pennsauken NJ 08110 Toll Free 800 678 8289 Outside U S 856 406 1020 Fax 856 406 1025 ...