Pb
Battery
»
progam
This
program
allows
you
to
charge
or
discharge
your
Lead
Acid
batteries.
Charge
This
function
allows
to
charge
lead
Acid
batteries
from
2
up
to
20
Volts.
Please
input
the
charge
current
and
nominal
voltage
of
the
battery
connected.
Please
note
that
Lead
Acid
batteries
should
be
charged
slowly,
with
0.1C
charge
current
(
1/10
of
their
total
capacity).
It
is
necessary,
in
most
time,
to
disable
the
safety
timer
to
avoid
partial
charge.
Discharge
Same
as
above
function,
for
discharging
the
battery.
«
Program
Select
»
Menu
detail
Your
charger
is
featuring
a
user
memory
handling
up
to
5
customised
programs.
You
can
save
or
recall
these
programs
at
any
time
by
getting
in
this
menu.
Save
To
save
a
program,
select
a
memory
slot
between
1
and
5,
then
validate.
Choose
the
battery
type,
the
voltage
if
necessary,
and
the
maximum
charge
capacity.
Press
«
Enter
»
during
3
seconds,
a
«
*
»symbol
should
blink
in
top
right
of
the
screen.
Press
Enter
and
select
the
charge
current,
and
validate
again.
For
Lithium
batteries,
please
check
the
number
of
cells
and
validate.
Then,
press
again
“Enter”
for
3
seconds,
the
message
“Save”
will
appear
for
a
few
instants,
the
program
is
now
saved
in
the
charger
memory.
Load
This
function
allows
you
to
load
a
previously
saved
program.
Choose
the
program
number
you
wish
to
load,
and
press
«
Enter
»
for
3
seconds.
You
will
then
arrive
to
the
battery
charge
/
discharge
program
you
had
recorded
in
this
program.